Bridgestone Retail Operations, LLC<br />

PROJECT MANUAL<br />

Version: January 2012<br />

c. Vertical Stiles: 3-1/2” wide.<br />

d. Bottom Rail: 6-1/2” wide, complying with ANSI Requirements.<br />

e. Glass: 1-5/16” insulated.<br />

f. Glazing Stops: Square.<br />

g. Finish: Same as storefront.<br />

2.04 MATERIALS<br />

A. Extruded Aluminum: ASTM B221 (ASTM B221M).<br />

B. Sheet Aluminum: ASTM B209 (ASTM B209M).<br />

C. Fasteners: Stainless steel.<br />

D. Concealed Flashings: 0.018 inch thick galvanized steel.<br />

E. Perimeter Sealant: Specified in Section 07900.<br />

F. Glass: Safety glass to be provided as required by code.<br />

G. Glazing Gaskets: Type to suit application to achieve weather, moisture, and air infiltration<br />

requirements.<br />

2.05 HARDWARE<br />

A. Door Hardware: Storefront manufacturer's standard type to suit application.<br />

1. Include for each door weather-stripping, sill sweep strip, threshold, pivots, narrow stile handle<br />

latch, dead bolt with interior lever and closer.<br />

2. Pull to be flat plate style (to accommodate BSRO signage on all exterior doors).<br />

B. Weather-stripping: Wool pile, continuous and replaceable; ADA compliant; provide on all doors.<br />

C. Threshold: Extruded aluminum, one piece per door opening, ribbed surface; provide on all doors.<br />

D. Drip Caps: Refer to drawings.<br />

2.06 FABRICATION<br />

A. Submit shop drawings as outlined in Section 01300. Do not begin fabrication until shop drawings<br />

have been approved.<br />

B. Fabricate components in strict accordance with manufacturers printed instructions.<br />

C. Reinforce framing members for imposed loads.<br />

PART 3 EXECUTION<br />

3.01 INSTALLATION<br />

A. Install wall system in strict accordance with manufacturer's printed instructions.<br />

B. Attach to structure to permit sufficient adjustment to accommodate construction tolerances and<br />

other irregularities.<br />

C. Provide alignment attachments and shims to permanently fasten system to building structure.<br />

D. Align assembly plumb and level, free of warp or twist. Maintain assembly dimensional tolerances,<br />

aligning with adjacent work.<br />

E. Provide thermal isolation where components penetrate or disrupt building insulation.<br />

F. Install sill flashings. Turn up ends and edges; seal to adjacent work to form water tight dam.<br />

G. Coordinate attachment and seal of perimeter air and vapor barrier materials.<br />

H. Pack fibrous insulation in shim spaces at perimeter of assembly to maintain continuity of thermal<br />

barrier.<br />

I. Set thresholds in bed of mastic and secure.<br />

J. Install hardware using templates provided.<br />

K. Install glass and infill panels in accordance with Section 08800, using glazing method required to<br />

achieve performance criteria.<br />

L. Install perimeter sealant in accordance with Section 07900.<br />

M. Conduct hose stream test of storefront and door at time of punchlist.<br />

3.02 ADJUSTING<br />

A. Adjust operating hardware for smooth operation.<br />

METAL FRAMED STORE FRONTS – (INCLUDING HURRICANE RESISTANT) 08410 - Page 3 of 4