Bridgestone Retail Operations, LLC<br />

PROJECT MANUAL<br />

Version: January 2012<br />

E. Make delivery to job when notified by Contractor verifying that the job is ready to receive<br />

the work of this section and that arrangements have been made to properly store, handle<br />

and protect such materials and work.<br />

1.04 PROJECT CONDITIONS<br />

A. Contractor shall acquaint himself with all existing site conditions. If unknown active utilities<br />

are encountered during work, notify Architect promptly for instructions. Failure to notify will<br />

make Contractor liable for damage to these utilities arising from Contractor's operations<br />

subsequent to discovery of such unknown active utilities.<br />

1.05 FIELD MEASUREMENTS<br />

A. Make and be responsible for all field dimensions necessary for proper fitting' and<br />

completion of work. Report discrepancies to Civil Engineer before proceeding.<br />

PART 2 MATERIALS<br />

2.01 EPIC COMPONENTS<br />

A. Firestone Part Numbers<br />

1. Firestone EPIC Chambers - W56WMGTEC60<br />

2. Firestone EPIC Pan Sheet - W56WMGTES01<br />

3. Firestone EPIC Pans - W56WMGTEP01<br />

4. Firestone EPDM Geomembrane - various, see TIS online at<br />

www.firestonesp.com.<br />

5. EPIC Grommet - W56WMGTEG01<br />

6. Control valves, sensors, timers and pumps as specified in project plans.<br />

B. Connection pipe shall be 2" Schedule 40 PVC or ABS.<br />

C. Drainage lines shall be a 6" or larger Schedule 40 PVC or ABS unless specified otherwise<br />

in plans.<br />

D. EPIC supply lines shall be 3f4" or larger Schedule 40 PVC.<br />

E. Plastic Septic tank reservoir, size and make as specified in plans.<br />

F. Pump access cover or manhole as specified in plans.<br />

2.02 WATER SUPPLY LINES<br />

A. Water delivery systems supplying water to the Reservoir float valve to be installed<br />

according to plans with minimum delivery pressure of 20 p.s.i. and delivery volume of 12<br />

GPM per acre of turf.<br />

2.03 SAND AND GRAVEL FILL MATERIAL<br />

A. The sand shall meet EPIC specifications.<br />

B. The fine gravel shall meet EPIC specifications of #10 sieve - 1f4" diameter size or<br />

equivalent on approval.<br />

2.04 FERTILIZER AND AMENDMENTS<br />

A. Analysis 15-15-15 Best Endure<br />

B. Analysis 6-2-4 Tri C Organic Soil Conditioner/Fertilizer with Micronutrients<br />

C. Elemental Sulfur<br />

D. Granular Gypsum<br />

EPIC SYSTEM WATER MANAGEMENT 02488 - Page 2 of 7