Bismarck Real Estate Partners, Inc.<br />

PROJECT MANUAL<br />

C. Shop Paint: Rustguard 4150-6160 gray, low VOC shop coat primer, Devoe Coatings, by ICI<br />

and shall conform to the Steel Structures Painting Council Specifications 15-68T, Type 1.<br />

2.02 FABRICATION<br />

(A)<br />

(B)<br />

(C)<br />

(D)<br />

Steel joists shall be fabricated in accordance with the Standard Specifications for Open Web<br />

Steel Joists, K-Series.<br />

Provide extended ends, special depth ends, etc., where indicated on the drawings and, as job<br />

conditions require.<br />

Before application of shop coat, clean steel free of all foreign substances. Give all steel<br />

items one (1) shop coat.<br />

Camber all steel joists for roofs in accordance with the Standard Specifications for Open Web<br />

Steel Joists, K-Series.<br />

PART 3 - EXECUTION<br />

3.01 DESIGN<br />

A. Steel joists shall be designed by the manufacturer. The manufacturer's engineer shall be<br />

responsible for the design, adequacy and safety of all steel joists. Design shall be in<br />

accordance with the Standard Specifications for Open Web Steel Joists, K-Series.<br />

B. Unless otherwise noted, steel joists shall be designed as simply supported, uniformly loaded<br />

trusses with the top chord braced against lateral buckling. The uniform design load shall be<br />

the total safe uniformly distributed load as shown in the SJI Standard Load Table.<br />

C. When net uplift forces due to wind are shown on the drawings, the manufacturer shall design<br />

the joists, bridging and connections of the joists to the supporting structure for the net uplift.<br />

A single line of bottom chord bridging must be provided near the first bottom chord panel<br />

points whenever uplift due to wind forces is shown on the design drawings.<br />

D. When nonuniform or concentrated loads are shown on the drawings, the manufacturer shall<br />

design the joists in accordance with Standard Specification for Open Web Steel Joists,<br />

K-Series.<br />

3.02 ERECTION<br />

A. Steel joists shall be erected in accordance with the Standard Specifications for Open Web<br />

Steel Joists, K-Series.<br />

B. Thoroughly examine the structural steel and other supports on which the steel joist work is in<br />

any way dependent and notify the Owner's Representative in writing of any defects which<br />

would affect the satisfactory completion of this work. The starting of work in connection with<br />

open web steel joists shall imply acceptance of the underlying surfaces.<br />

C. During the construction period, the Contractor shall provide means for the adequate<br />

distribution of concentrated loads so that the carrying capacity of any joist is not exceeded.<br />

D. All bridging and bridging anchors shall be placed and joist ends fixed prior to the application<br />

of any loads.<br />

E. Roof structure is exposed and shall be painted. During on site storage keep joists clean and<br />

protected from the elements stored, and covered, to minimize rust. Field touch up painting<br />

shall be done with the same type of paint as the shop coat. Touch up shall include bare,<br />

abraded, welded and rusted areas.<br />

F. Repair or replace all damaged joists. CASCO shall be the sole judge as to whether a joist<br />

can be repaired or must be replaced.<br />

END SECTION<br />

STEEL JOISTS 05220 - Page 2 of 2