E. Threaded Plastic Pipe Jointing:<br />

1. Do not use solvent cement on threaded joints.<br />

2. Wrap joints with Teflon tape or use virgin Teflon lubricant.<br />

F. Bell and Socket Plastic Pipe Jointing: Cement joints in accordance with ASTM D2855.<br />

3.04 SLEEVING<br />

A. Provide sleeves for both piping and control wiring where either passes under paved<br />

surfaces.<br />

1. Depths of sleeves shall be same as that required for piping at each location or<br />

condition.<br />

2. Extend sleeves 12 inches beyond paving at each end.<br />

3. Install permanent benchmark at top of curbs for reference to sleeve locations.<br />

3.05 AUTOMATIC DRAIN VALVES<br />

3.06 VALVES<br />

A. Provide automatic low point drains on all zones. Provide two valves at lowest points of<br />

each zone, with each drain installed above a 12 inch x 12 inch x 12 inch deep area of<br />

coarse gravel.<br />

A. Do not locate beneath paved surfaces.<br />

B. Install plumb to within 1/16 inch.<br />

C. Locate within valve box with 6 inch deep layer of coarse gravel beneath bottom of valve.<br />

D. Top of quick coupler valves shall be 6 inches to top of valve box. Top of gravel layer shall<br />

be 3 inches below top of valve.<br />

E. Master Valve (if required on the Drawings):<br />

1. Locate immediately behind backflow preventor.<br />

2. Valve shall be energized by master valve circuit on automatic controller.<br />

3.07 SPRINKLERS<br />

A. Install plumb to within 1/16 inch with top collar, not nozzle, flush with finish grade.<br />

B. Provide swing joint with each sprinkler except where entire head is raised above grade<br />

and/or where rigid riser piping is required.<br />

C. Heads adjacent to paving and curb: Locate between 6 and 12 inches from edge of paving<br />

or back of curb to prevent car overhang to conflict with a fully extended sprinkler.<br />

3.08 ELECTRICAL CONNECTIONS AND CONTROL WIRE<br />

A. Conform to the National Electrical Code (NEC) and local electrical codes.<br />

B. Provide electrical connection to system as designated on the Drawings and as specified<br />

herein.<br />

C. Wire Placement:<br />

1. Do not run control and power supply wiring in same conduit.<br />

2. Provide continuous runs of wire between controller and valves. Splices shall be<br />

made with one of following:<br />

a. Watertight below ground electrical junction boxes.<br />

b. Water-tight connectors, such as utilized for valves, and located within<br />

valve box for ease of locating.<br />

c. The location of electrical splices shall be shown on the As-Built<br />

drawings.<br />

3. Bury control wire beside pipe in same trench. Bundle and tape together at not<br />

more than 10 ft in-tervals.<br />