Bridgestone Retail Operations, LLC<br />

PROJECT MANUAL<br />

Version: January 2012<br />

PART 3 EXECUTION<br />

3.01 EXAMINATION<br />

A. Verify that surfaces to receive flashing are thoroughly dry, free from dirt, oil, grease and other<br />

materials, reasonably smooth and without any sharp edges, fins, loose or foreign materials that<br />

may damage membrane.<br />

1. Do not use open flame sources or any other means to expedite drying of adhesives, sealants<br />

or primers.<br />

B. Roughened surfaces that could cause damage shall be properly isolated from the membrane.<br />

C. Verify that locations to receive flashing are sloped so water that enters will drain to building exterior<br />

face.<br />

3.02 PREPARATION<br />

A. Properly fill voids of sheet flashing substrate surface greater than ¼ inch wide with appropriate<br />

material such as mortar or grout.<br />

B. Remove any moisture on the substrate prior to installation.<br />

3.03 INSTALLATION<br />

A. Coordination: Interface flashing work with adjacent and adjoining work to ensure weather<br />

resistance and durability of completed flashing.<br />

B. Install sheet flashing in accordance with manufacturer’s written instructions and details.<br />

C. Upon completion of the masonry veneer installation, trim the sheet flashing as indicated on the<br />

Drawings to form a drip edge. Do not terminate sheet flashing within the mortar joint.<br />

END OF SECTION<br />

EPDM SHEET FLASHING 07650 - Page 2 of 2