Invitation to Bid<br />

23. Are the tops of handrails at ramps between 33” and 39” above the ramp<br />

surface?<br />

24. Are 10” minimum long horizontal extensions provided at the top and<br />

bottom of each ramp handrail?<br />

25. Is the diameter of each ramp handrail gripping surface between 1 ¼” - 2"?<br />

D. CUSTOMER ENTRY DOOR<br />

26. Is the net clear width of one door leaf when open 90 o at least 31 3/8” at<br />

each customer entry that is on an accessible route?<br />

27. Is the pull side clear floor area maneuvering space at least 17” wide beyond<br />

the strike of each<br />

customer entry door that is on an accessible route?<br />

28. Is the pull sidemaneuvering space at least 59” deep for front approach or<br />

48" deep for side approach at each customer entry door that is on an<br />

accessible route?<br />

29. Is the push side maneuvering clearance at least 10” wide beyond the strike<br />

of each customer entry<br />

door that is on an accessible route, if there is both a closer and a latch on<br />

the door (or 0" required beyond the latch if not both a closer and a latch)?<br />

30. Is the push side maneuvering space at least 48" deep for front approach or<br />

42" deep for side approach at each customer entry door that is on an<br />

accessible route?<br />

31. Is the threshold no higher than ¼” vertical or ½” and beveled at each<br />

customer entry door that is on<br />

an accessible route?<br />

32. Are the handles operable with a closed fist or flail hand at each customer<br />

entry door that is on an accessible route?<br />

33. Is the slope of the maneuvering space no steeper than 3% in any direction<br />

at the exterior side of each customer entry door that is on an accessible<br />

route?<br />

34. If all customer entry doors are not accessible, is there a sign with the ISA<br />

(International Symbol of Accessibility) at each accessible entry door and an<br />

ISA sign with a directional arrow at each non-accessible customer entry<br />

door, directing customers to an accessible door?<br />

© 2002 - Universal Designers & Consultants, Inc.<br />