Bridgestone Retail Operations, LLC<br />

PROJECT MANUAL<br />

Version: January 2012<br />

B. See Section 01780 – Closeout Submittals, for additional warranty requirements.<br />

PART 2 PRODUCTS<br />

2.1 MANUFACTURERS<br />

A. Acceptable Manufacturer: ALACO Ladder Co., which is located at: 5167 G St. ;<br />

Chino, CA 91710-5143; Toll Free Tel: 888-310-7040; Tel: 909-591-7561; Email:<br />

request info (sales@alacoladder.com); Web: www.alacoladder.com<br />

B. Requests for substitutions will be considered in accordance with provisions of<br />

Section 01600.<br />

2.2 MATERIALS<br />

A. Extruded Aluminum Profiles: ASTM B 221, ASTM B 210, ASTM B 308, Alloy 6061-<br />

T6; standard mill finish.<br />

B. Aluminum Sheet and Plate: ASTM B 209, Alloy 6061-T6; standard mill finish.<br />

C. Fasteners: Aluminum solid aircraft rivets rated at 300 lbs shear strength.<br />

D. Cast fittings, connectors and rung ends: Cast Aluminum alloy 356<br />

2.3 LADDERS<br />

A. Ladders - General: Comply with ANSI A14.3 and OSHA regulations.<br />

B. Folding Wall Ladders: 24 inches wide.<br />

1. Slope: 60 degrees; 6-inch wide aluminum nonslip steps mounted on 10-13/32<br />

inches centers to 5-1/4 inch aluminum side rails.<br />

2. Provide handrails of 1-1/4 in round serrated aluminum tubing with cast or<br />

extruded aluminum fittings and four mounting brackets.<br />

3. Fasten each step with not less than eight aluminum aircraft rivets.<br />

4. Furnish with mounting bracket-slide assemblies to allow flat storage against<br />

wall and non-marking solid rubber feet for secure installation.<br />

2.4 FINISHES<br />

A. Provide all aluminum in standard mill finish.<br />

PART 3 EXECUTION<br />

3.1 EXAMINATION<br />

A. Do not begin installation until substrates have been properly prepared.<br />

B. If substrate preparation is the responsibility of another installer, notify Owner and<br />

Architect of unsatisfactory preparation before proceeding.<br />

3.2 INSTALLATION<br />

A. Install in accordance with manufacturer's instructions and approved shop drawings,<br />

and in compliance with ANSI A14.3 and OSHA 1910.27.<br />

3.3 PROTECTION<br />

A. Protect installed products until completion of project.<br />