Bridgestone Retail Operations, LLC<br />

PROJECT MANUAL<br />

Version: January 2012<br />

SECTION 06193<br />

PLATE CONNECTED WOOD TRUSSES<br />

PART 1 GENERAL<br />

1.01 SECTION INCLUDES<br />

A. Prefabricated wood trusses for roof. This includes truss to girder connectors as required.<br />

B. Bridging, bracing, and anchorage.<br />

C. Related Sections:<br />

1. Section 06100 – Rough Carpentry<br />

1.02 SUBMITTALS<br />

A. Submit the following under provisions of section 01300.<br />

1. Product Data: Submit product data, including manufacturer’s installation instructions.<br />

2. Shop Drawings: Indicate framing system, sizes and spacing of members, loads and cambers,<br />

bearing and anchor details, bridging and bracing, connecting plates, and framed openings.<br />

3. Certification: Submit design calculations, which will include all truss to girder connectors.<br />

Design calculations to be sealed by a Professional Engineer licensed in state where project is<br />

located.<br />

4. Truss manufacturer to provide a certification letter stating that the fire retardant trusses will<br />

maintain their structural integrity after the fire treating process.<br />

1.03 QUALITY ASSURANCE<br />

A. Manufacturer: Company specializing in manufacture of prefabricated wood trusses, with three-year<br />

minimum experience.<br />

B. Design trusses under direct supervision of Professional Engineer experienced in structural framing<br />

design of trusses, licensed in state where Project is located. Comply with the “National Design for<br />

Stress Graded Lumber and its fastenings”, as published by NFPA. And “Design Specifications for<br />

Light Metal Place Connected Wood Trusses”, as published by TPI.<br />

C. Refer to drawings and government codes for live and dead load requirements.<br />

D. Lumber grading agency: Certified by ALSC.<br />

E. Truss Plates: I accordance with Truss Plate Institute.<br />

F. Regulatory Requirements:<br />

1. Conform to applicable code for loads, seismic zoning, and other government load criteria.<br />

2. Conform to applicable code for fire retardant requirements.<br />

3. Conform to UL requirements to achieve rating indicated.<br />

G. Fire retardant material – refer to Section 06100.<br />

PART 2 PRODUCTS<br />

2.01 MANUFACTURERS<br />

A. Member of TPI and having minimum experience level indicated.<br />

2.02 MATERIALS<br />

A. Lumber Grading Rules: NFPA.<br />

B. Plywood Gussets: Graded by APA; fir wood species, lumber core, standard grade, waterproof<br />

glue; 19 percent maximum moisture content.<br />

C. Steel Connectors: ANSI/ASTM A446 steel, Grade A; galvanized; die stamped with integral teeth<br />

D. Fasteners: galvanized; size and type to suit condition<br />

E. Bearing Plate Anchors: Bolts or ballistic fasteners for anchorages to steel.<br />

F. Wood blocking: Softwood lumber, fir species, construction grade, maximum moisture content of 19<br />

percent.<br />

G. Fire retardant material – refer to Section 06100.<br />

PLATE CONNECTED WOOD TRUSSES 06193 - Page 1 of 2