Bridgestone/Firestone – Lakewood, CO Addendum June 21, 2012<br />

PSI Project No. 532281 Page 6 of 6<br />

<br />

Some increase in moisture content is inevitable as a result of development and associated<br />

landscaping. However, extreme moisture content increases can be largely controlled by<br />

proper and responsible site drainage, building maintenance and irrigation practices.<br />

Utility backfill in areas supporting slabs should be moisture conditioned or dried by<br />

scarification, and compacted. Backfill in interior and exterior water and sewer line trenches<br />

should be uniformly compacted.<br />

Exterior slabs should be isolated from the building. These slabs should be reinforced to<br />

function as independent units. Movement of these slabs should not be transmitted to the<br />

building foundations or superstructures.<br />

PSI appreciates the opportunity to submit this addendum and look forward to working with you<br />

on this project. If you have any questions concerning our report, please contact our office.<br />

Respectfully Submitted,<br />

PROFESSIONAL SERVICE INDUSTRIES, INC.<br />

ELECTRONIC COPY<br />

ELECTRONIC COPY<br />

Matthew R. Satterfield, P.E.<br />

Project Engineer<br />

Kyle R. Duitsman, P.E.<br />

Department Manager<br />

Cc: Mays & Company