Ex. No.<br />

4.6<br />

K1<br />

K2<br />

L+<br />

N/<br />

M<br />

M<br />

L+<br />

L / L+<br />

L+ M<br />

Wiring of the protective door and the safety monitor<br />

Important Hardware Component Settings<br />

M<br />

L+<br />

1.<br />

Y1<br />

K1<br />

E1(<br />

+ )<br />

3SE2<br />

840-6XX00<br />

DP/AS-i LINK Advanced<br />

Prerequisites:<br />

■ The DP/AS-INTERFACE LINK Advanced is mounted and connected<br />

to the AS-i line.<br />

■ The AS-i power supply unit is connected to the AS-i line.<br />

■ The AS-i slaves are not yet connected.<br />

■ The slaves that are to be connected have default address "0"<br />

(delivery status).<br />

120 Functional Example No. CD-FE-I-035-V10-EN<br />

K1<br />

K2<br />

K2<br />

1.<br />

32<br />

Start<br />

1.<br />

13<br />

1.<br />

23<br />

1. Y1<br />

2. 13<br />

2.<br />

23<br />

2.<br />

Y1<br />

AS-i+<br />

AS-i-<br />

1. Y2<br />

2.<br />

Y2<br />

AS-i<br />

1<br />

2<br />

3<br />

1 READY<br />

2 ON<br />

3 FAULT<br />

M<br />

Service<br />

1<br />

2<br />

3<br />

CONFIG<br />

1.<br />

14<br />

1.<br />

24<br />

PE<br />

2.<br />

14<br />

2.<br />

24<br />

2.<br />

32<br />

E2(<br />

-)<br />

31<br />

41<br />

PIN<br />

1 = Terminal 12<br />

PIN<br />

2 = Terminal 11<br />

PIN<br />

3 = n.<br />

c.<br />

PIN<br />

4 = n.<br />

c.<br />

Magnet<br />

3<br />

32<br />

42<br />

4<br />

5<br />

2<br />

Actuator<br />

11<br />

12<br />

1<br />

21<br />

22<br />

F-<br />

IN2<br />

Protective door<br />

F-<br />

IN1<br />

ADDR<br />

AS-i<br />

FAULT<br />

SIEMENS<br />

3RK1205-0BQ00-0AA3<br />

3<br />

4<br />

5<br />

2<br />

1<br />

Closed<br />

Procedure/Working on the DP/AS-INTERFACE LINK Advanced:<br />

■ Switch on the AS-i power supply unit so that the DP/AS-<br />

INTERFACE LINK Advanced is in operation<br />

■ Connect each AS-i slave to the AS-i line and allocate the<br />

desired slave address (K45F module, address 1 / K45 standard<br />

module, address 2).<br />

SYSTEM AS-i line 1 Lifelist Change address<br />

Change slave address<br />

■ Adopt the actual configuration of the slave as the defined<br />

configuration in the DP/AS-INTERFACE LINK Advanced<br />

SYSTEM AS-i line 1 Lifelist Actual -> Defined<br />

Actual -> Adopt defined<br />

21<br />

Result:<br />

All displays for the AS-i line on the DP/AS-INTERFACE LINK Advanced<br />

are off or green, i.e. all slaves have been successfully<br />

integrated.<br />

22<br />

13<br />

14<br />

3SE2120-1GW<br />

PIN<br />

1 = Terminal 21<br />

PIN<br />

2 = Terminal 22<br />

PIN<br />

3 = n.<br />

c.<br />

PIN<br />

4 = n.<br />

c.<br />

Open