Ex. No.<br />

3.5<br />

Note Diagram<br />

<strong>Safety</strong> shutdown group<br />

The safety shutdown group must be set.<br />

This number is compared with the safety-related mechanical assignment<br />

on the terminal module - this is not visible from outside - and<br />

must match this.<br />

Default: Not assigned<br />

Rated operating current<br />

Here, the rated operating current is entered, which the feeder can<br />

conduct without any interruption (switching device and motor) (rated<br />

motor current). The current that can be set depends on the motor<br />

starter current range (e.g. 0.3 A to 3 A; 2.4 A to 8 A; 2.4 A to 16 A).<br />

This can be set in 10 mA steps within a specific range.<br />

-> Wide range setting<br />

Default: Minimum value<br />

Current limit<br />

Upper current limit:<br />

The mechanical system/equipment is more difficult to move - e.g. if<br />

the bearings are damaged, the mixture being mixed is too viscous<br />

-> current is greater than that set<br />

Lower current limit:<br />

The mechanical system/equipment is easier to move, e.g. the material<br />

being processed in the plant or system is no longer present, drive<br />

belts broken<br />

-> current is less than that set<br />

Protection by evaluating how the current limit is violated<br />

Default: Alarm<br />