Overview of interfaces and communication scope<br />

Bus interface<br />

1<br />

2<br />

SIMATIC<br />

S7 F-CPU<br />

receive<br />

10 PZD consistent<br />

send<br />

4 PZD consistent<br />

Detailed interface description<br />

send<br />

10 PZD consistent<br />

receive<br />

4 PZD consistent<br />

Explanation regarding 1<br />

F-CPU Address Data SIMOTION Address<br />

EWx (*) Sign of life from the drive (INT)<br />

Error message output by the drive (INT)<br />

Control word from the drive (INT)<br />

Redundant coarse position (INT)<br />

Coarse position information (INT)<br />

Actual speed from the drive (INT)<br />

CRC via speed (INT)<br />

Calculated encoder module start CRC (WORD)<br />

CRC via redundant coarse position (INT)<br />

ARRAY [x] ... PQW<br />

EWx+ 9<br />

Detailed interface information<br />

Function block version from the SIMOTION function block (INT) ARRAY [x+9] ... PQW<br />

(*) If the data received are not displayed in the process image<br />

of the F-CPU, communication in the standard program has to<br />

be established using the emitter and receiver blocks SFC14<br />

("DP_RD_DAT").<br />

Bit memory address areas are required to transfer data into<br />

the safety program.<br />

SIMOTION SINAMICS<br />

3<br />

4<br />

receive<br />

4 PZD<br />

send<br />

1 PZD<br />

send<br />

4 PZD<br />

receive<br />

1 PZD<br />

SMx<br />

Function Example No. MC-FE-I-004-V11-EN 441<br />

Ex. No.<br />