Overview of inputs and outputs<br />

Overview of connected push buttons:<br />

No. HW component (type) Address Symbolic address Default Function<br />

1 Push button (NO) E 0.0 START_ACTUATOR "0" This button switches on the<br />

ACTUATOR indicator light .<br />

2 Push button (NO) E 0.1 ACK_ESTP_ACTUATOR "0" This button acknowledges the<br />

emergency stop circuit.<br />

3 Push button(NO E 0.2 ACK_PASS_ACTUATOR "0" This button acknowledges the<br />

manual reintegration of the<br />

ACTUATOR indicator light.<br />

4 Emergency stop push button<br />

at F-DI (NC/NC)<br />

Overview of connected indicator light:<br />

E 1.0 ESTP_ACTUATOR "1" This button switches off the<br />

ACTUATOR indicator light .<br />

No. HW component (color) Address Symbolic address After startup Meaning<br />

5 Indicator light<br />

(white)<br />

6 Indicator light<br />

(white)<br />

7 Indicator light<br />

(green)<br />

8 Indicator light at F DO<br />

(yellow)<br />

9 Indicator light at F DO<br />

(yellow)<br />

A 0.0 REQ_ACK_ESTP_ACTUATOR "1" The switched on indicator light<br />

indicates, that the emergency<br />

stop circuit requires acknowledgement.<br />

A 0.1 REQ_ACK_PASS_ACTUATOR "0" The switched on indicator light<br />

indicates, that acknowledgement<br />

for manual reintegration<br />

of the ACTUATOR indicator<br />

light is necessary.<br />

A 0.2 PASSIVATION_ON "0" The switched on indicator light<br />

indicates the current passivation.<br />

A 7.0 ACTUATOR "0" The indicator light simulates<br />

the "hazardous loads".<br />

The switched on indicator light<br />

indicates the "hazardous<br />

loads" being switched on<br />

A 7.1 TEST "1" The indicator light is only used<br />

to demonstrate the passivation<br />

of the entire module. The<br />

indicator light has no other<br />

function.<br />

Normally, TEST is always<br />

switched on. TEST is only<br />

switched off if F-DI is passivated.<br />

Functional Example No. AS-FE-I-011-V10-EN 321<br />