Ex. No.<br />

8 Flowchart<br />

The following flow chart shows the correlation (for a better<br />

overview, operational stoppage is not displayed here):<br />

N<br />

Y<br />

N<br />

Begin<br />

Motor running?<br />

N<br />

Emergency stop<br />

unlocked?<br />

Y<br />

Readback error?<br />

N<br />

Acknowledgement<br />

necessary?<br />

N<br />

Start command?<br />

Y<br />

MICROMASTER<br />

starts motor<br />

Motor runs<br />

Y<br />

Y<br />

Acknowledged?<br />

MICROMASTER is<br />

supplied with voltage<br />

260 Functional Example No. AS-FE-I-008-V11-EN<br />

Y<br />

N<br />

Readback error?<br />

N<br />

<strong>Safety</strong> door open?<br />

(simulated<br />

signal)<br />

N<br />

Emergency stop<br />

pressed?<br />

N<br />

Y<br />

Y<br />

Y<br />

MICROMASTER sets<br />

motor in stop<br />

MICROMASTER and motor<br />

are electrically isolated<br />

from the line supply<br />

Motor in stop and<br />

electrically isolated<br />

from the line supply<br />

MICROMASTER and motor<br />

are electrically isolated<br />

from the line supply<br />

Motor in stop and<br />

electrically isolated<br />

from the line supply<br />

Stop category 1 Stop category 0<br />

G_FB_XX_151