Ex. No.<br />

2.7<br />

Powering-up and powering-down the drive<br />

The drives can be started or stopped when the protective<br />

doors are closed and Emergency Stop button S9 is released.<br />

■ When button S2a/b ("On") is pressed, safety combination<br />

A4 is brought into the operational state. The internal line<br />

contactor of the rectifier unit is energized.<br />

■ When button S2a/b ("On") is pressed, contactor K3a/b is<br />

energized and latches; time relay K2a/b is simultaneously<br />

energized. The internal safety relay is energized and a 1 signal<br />

is entered at contact 65 (controller enable) of drive A/B.<br />

The drive restarts.<br />

426 Functional Example No. MC-FE-I-002-V11-EN<br />

■ When button S1a/b ("Off") is pressed, contactor K3a/b is no<br />

longer energized. The drop-out delay of time relay K2a/b is<br />

simultaneously started. When contactor K3a/b drops-out, a<br />

0 signal is entered at contact 65 (controller enable) of the<br />

drive A/B. The drive is immediately braked down to 0 speed<br />

and the pulses cancelled. The internal safety relay of the<br />

drive is no longer energized after the drop-out delay time<br />

of time relay K2a/b has expired. The protective doors can be<br />

opened.