Ex. No.<br />

10 The status of the sensors defines the detection zone numbers<br />

(bits 0-2 of the cyclic output data). This defines which detection<br />

and warning zone is active. Possible activation in this example:<br />

■ zone pair detection zone 1 and warning zone 1 or<br />

■ zone pair detection zone 2 and warning zone 2<br />

If you want to expand the example in such a way as to work<br />

with three or (maximum) four zone pairs, you can use the already<br />

prepared program sequences (further information<br />

given on page 311).<br />

The sensors for switching the detection zones are directed to<br />

a fail-safe input module of the ET 200S. In case of a failure at<br />

this input module, switching between the detection zones is<br />

not possible anymore. This error is detected and sets the failsafe<br />

output module into fail-safe mode (indicator light is<br />

switched off).<br />

Reaction times<br />

For calculating the max. reaction time of your F-system please<br />

use the Excel file (Cotia table), which is available for S7 Distributed<br />

<strong>Safety</strong> V 5.3. This file is available on the internet:<br />

http://support.automation.siemens.com/WW/view/en/<br />

19138505<br />

Prepared detection and warning zones<br />

Apart from the STEP 7 project, both prepared zone pairs<br />

(SF1-WF1, SF2-WF2) are also available as a separate download<br />

file. Chapter 4 describes how to load these configuration data<br />

into the LS4. The prepared zone pairs are illustrated below for<br />

a first impression of the parameterization software LS4Soft.<br />

Note<br />

The contours of the detection and warning zones used<br />

in the example project are rectangles. The software<br />

LS4Soft also offers the possibility of perameterizing<br />

other contours (e.g. semi circles) as zone delimiters.<br />