Ex. No.<br />

7<br />

Operating instructions<br />

Prerequisite:<br />

■ Hardware configuration of STEP 7 and safety program are<br />

in the S7-CPU<br />

■ Emergency stop unlocked<br />

■ No passivation of the F-DI/F-DO<br />

Warning!<br />

The instructions listed in the table below should first<br />

be performed without activated load circuit.<br />

Motor ON/OFF<br />

No. Instruction Result/Note<br />

1 Press the acknowledgement<br />

push button and release it.<br />

2 Press the push button for<br />

start request and release it.<br />

3 Press the push button for<br />

stop request and release it.<br />

Emergency stop<br />

No. Instruction Result/Note<br />

1 If the motor is started for the<br />

first time: Press the acknowledgement<br />

push button<br />

If not: No. 2<br />

2 Press the push button for<br />

start request and release it.<br />

3 Press the emergency stop<br />

push button.<br />

4 Unlock the emergency stop<br />

push button<br />

5 Press the push button for<br />

start request and release it.<br />

Necessary before starting the<br />

motor for the first time.<br />

Contactors K1 and K2 are activated;<br />

due to this the motor<br />

starts<br />

Contactors K1 and K2 drop out;<br />

due to this the motor stops<br />

An acknowledgement is required<br />

before starting the motor<br />

for the first time.<br />

Contactors K1 and K2 are activated;<br />

due to this the motor<br />

starts<br />

Contactors K1 and K2 drop out:<br />

The motor stops<br />

–<br />

Contactors K1 and K2 are not activated,<br />

the motor does not<br />

start.<br />

Starting the motor is only possible<br />

after an acknowledgement.<br />

258 Functional Example No. AS-FE-I-007-V10-EN<br />

Welding of a contactor<br />

No. Instruction Result/Note<br />

1 If the motor is started for the<br />

first time: Press the acknowledgement<br />

push button<br />

If not: No. 2<br />

2 Press the push button for<br />

start request and release it.<br />

3 Press the STOP push button<br />

and keep the coil of contactor<br />

K1 or K2activated.<br />

4 Press the push button for<br />

start request and release it.<br />

An acknowledgement is required<br />

before starting the motor<br />

for the first time.<br />

Contactors K1 and K2 are activated;<br />

due to this the motor<br />

starts<br />

Simulated welding of the contactor.<br />

F output for K1 and K2 is not<br />

switched.