Key performance data<br />

Load memory and working memory<br />

Load memory<br />

Total<br />

approx. 54 k<br />

Working memory approx. 39 k<br />

Cycle time<br />

Total cycle time<br />

(typical)<br />

Example code<br />

approx.<br />

3ms<br />

Standard and safety program<br />

The example code supplied is fully functional for the described<br />

application. The individual functions of the example code are<br />

explained in the following Chapters so that you are in a position<br />

to implement your own projects.<br />

Note<br />

In this example code, passwords are used for the safety<br />

functions. These are as follows:<br />

S7 safety program and HW Config: siemens<br />

STARTER <strong>Safety</strong> Screens: 12345<br />

Settings in the hardware configuration<br />

Properties of the CPU<br />

Before the safety functions of the CPU can be used, they must<br />

be released. The properties window of the CPU is opened by<br />

double clicking on the CPU317F-2.<br />

Under the Protection tab, the safety functions of the CPU are<br />

enabled by selecting the following functions:<br />

■ Level of protection; 1: Access protect for F CPU,<br />

■ Activate Removable with password,<br />

■ Enter a password (in this example code, siemens),<br />

■ Activate CPU contains safety program.<br />

Properties of the F-DI module<br />

The signal sources for the safety functions (pushbuttons to<br />

acknowledge STO, SS1, SLS and Emergency Stop) are read-in<br />

using the fail-safe module DI24xDC24V (6ES7326-1BK01-<br />

0AB0). The Properties dialog box opens after double clicking<br />

on the module. The properties of the module can be parameterized<br />

by selecting the Parameters tab.<br />