Ex. No.<br />

10 Network 3<br />

Additionally contained in OB 1 is the "FB LS4", which, however,<br />

is not processed. It only serves as preparation it is to<br />

be used. Please note: Before calling the "FB LS4" the "Proxy-<br />

Enable" bit must be permanently set to "1".<br />

The "FB LS4" enables automatic parameterization when exchanging<br />

the LS4.<br />

The fail-safe program has the following structure:<br />

F-Call<br />

(FC1)<br />

FB"SET_ACT"<br />

(FB3,DB3)<br />

FB"FIELD_PAIR_SWITCHING"<br />

(FB4,DB4)<br />

FC"REINTEGRATION"<br />

(FC3)<br />

FC "FMAIN" (FC 2)<br />

The calls of the F-blocks are coordinated from here.<br />

Network 1<br />

FB 3, DB 3 is called here:<br />

...<br />

"ACK"<br />

"OSSD"<br />

"COND"<br />

EN<br />

ACK<br />

OSSD<br />

COND1<br />

FC"FMAIN"<br />

(FC2)<br />

"INSTANZ_<br />

FB3"<br />

"SET_ACT"<br />

ACTUATOR<br />

ENO<br />

"ACTUATOR"<br />

312 Functional Example No. AS-FE-I-010-V11-EN<br />

G_FB_XX_185<br />

G_FB_XX_187<br />

Parameter Note<br />

ACK Acknowledgement signal<br />

OSSD <strong>Safety</strong>-relevant output of LS4.<br />

COND1 Starting condition defined in OB 1 (or OB 35).<br />

ACTUATOR Indicator light<br />

Network 2<br />

FB 4, DB 4 is called here:<br />

Inputs: Position switches which define which zone pair is active.<br />

The inputs "SEN_FIELD3" and "SEN_FIELD4" are not used<br />

in this example and are therefore assigned with memory bits<br />

as dummies.<br />

Outputs: Detection zone number (bit 0 to 2) of the cyclic output<br />

data.<br />

Network 3<br />

...<br />

"SEN_<br />

FIELD1"<br />

"SEN_<br />

FIELD2"<br />

"SEN_<br />

FIELD3"<br />

"SEN_<br />

FIELD4"<br />

...<br />

EN<br />

EN<br />

SEN_<br />

FIELD1<br />

SEN_<br />

FIELD2<br />

SEN_<br />

FIELD3<br />

SEN_<br />

FIELD4<br />

"INSTANZ_<br />

FB4"<br />

"FIELD_PAIR_<br />

SWITCHING"<br />

"REINTEG<br />

RATION"<br />

FIELD<br />

BIT0<br />

FIELD<br />

BIT1<br />

FIELD<br />

BIT2<br />

ENO<br />

ENO<br />

"FIELD<br />

BIT0"<br />

"FIELD<br />

BIT1"<br />

"FIELD<br />

BIT2"<br />

Here the FC 3 is called for reintegration of passivated modules<br />

(F-DI / F-DO) and the LS4.<br />

G_FB_XX_186<br />

G_FB_XX_188