Ex. No.<br />

4<br />

The following communication variables have to be created in<br />

the I/O configuration:<br />

■ I/O input and output variables for sign-of-life monitoring<br />

via the CU (position 1,2)<br />

■ Transmit and receive arrays for establishing communication<br />

with the safety control 10/4 words (position 3,4)<br />

■ Redundant coarse position information from the axis<br />

encoder module SMx (position 5)<br />

■ Encoder status of the axis encoder module SMx (position 6)<br />

Integration of the function block "C_DRIVE"<br />

into the application<br />

Integration of c_drive<br />

448 Function Example No. MC-FE-I-004-V11-EN<br />

Possible responses in the SIMOTION application<br />

Immediate stop in the event of an axis monitoring fault<br />

If the axis monitoring function has not been enabled, the axis<br />

performs an emergency stop.<br />

Default setting for stop command with active axis standstill<br />

monitoring<br />

If the axis performs an operational stop, a cyclic stop command<br />

is preset.