Ex. No.<br />

2.7<br />

Safe standstill for several non-interlocked protective doors and several drives, Emergency Stop implemented using<br />

safety combinations<br />

Minimum circuit for the "safe standstill" with SIMODRIVE function<br />

Function description<br />

A structure in compliance with EN 954-1 control Category 3 and<br />

EN 1037 can be implemented using four SIGUARD safety combinations<br />

for Emergency Stop and protective doors. The drives are<br />

shut down (stopped) according to stop function Category 1 according<br />

to EN 60204-1.<br />

■ <strong>Safety</strong> combinations for Emergency Stop and protective door<br />

monitoring functions correspond to Category 4 (instantaneous<br />

enable circuit) or Category 3 (delayed enable circuit).<br />

■ Circuits for Emergency Stop and protective door monitoring<br />

are monitored through 2 channels in a cross-circuit proof fashion.<br />

424 Functional Example No. MC-FE-I-002-V11-EN<br />

■ Switches S3 and S8 are positively opening position switches<br />

corresponding to EN 1088.<br />

■ The drives are shut down via the internal safety relays.<br />

■ The on circuits of the safety combinations A1 to A4 monitor<br />

whether the internal line contactor of the rectifier unit has<br />

dropped-out after and Emergency Stop or whether time relay<br />

K2a/b and contactors K3a/b have dropped-out after opening<br />

the protective door circuits (this is necessary is the sense of<br />

control Category 3 according to EN 954-1!).