Ex. No.<br />

2.4<br />

Safe standstill for non-interlocked protective doors, implemented with one safety combination<br />

"Safe standstill" with SIMODRIVE for a non-interlocked protective door with safety combination, stop Category 1, Category 3 acc. to EN 954-1<br />

Function description<br />

A structure in compliance with EN 954-1 control Category 3 and<br />

EN1037 can be implemented using one SIGUARD safety combination<br />

for the protective doors. The drive is shut down (stopped)<br />

according to stop function Category 1 according to EN 60204-1.<br />

■ <strong>Safety</strong> combination for protective door monitoring functions<br />

corresponds to Category 4 (instantaneous enable circuit)<br />

or category 3 (delayed enabled circuit).<br />

■ Circuit for protective door monitoring is monitored through<br />

2 channels in a cross-circuit proof fashion.<br />

418 Functional Example No. MC-FE-I-002-V11-EN<br />

■ Switches S4 and S5 are positively opening position<br />

switches corresponding to EN 1088.<br />

■ The drive is shut down via the internal safety relay and the<br />

internal line contactor of the rectifier unit.<br />

■ The on circuit of safety combination A1 monitors whether<br />

the internal line contactor of the rectifier unit and the internal<br />

safety relay of the drive as well as contactor K1 have<br />

dropped-out after the protective doors have opened. (This<br />

is necessary in the sense of control Category 3 in compliance<br />

with EN 954-1!).