Function test<br />

After wiring the hardware components, you can check the inputs<br />

and outputs used with regard to their functionality (after<br />

downloading the S7 project).<br />

Inputs/outputs used<br />

No. Hardware<br />

component<br />

Testing inputs and outputs<br />

Requirements: The inputs and outputs have the default values<br />

specified under "Inputs/outputs used".<br />

Note<br />

The times DISCTIM1 and TIME_MAX mentioned in the<br />

following table are parameterized in FB 1 of the program<br />

code.<br />

Adress Symbol Signal<br />

(default value)<br />

1 Push button (NO) E 0.0 START "0" –<br />

2 Push button (NO) E 0.1 ACK "0" –<br />

3 Optical proximity switch E 1.0 MS_11 "0" Muting sensors<br />

4 Optical proximity switch E 1.1 MS_12 "0"<br />

"1": sensor detects material<br />

5 Optical proximity switch E 2.0 MS_21 "0"<br />

6 Optical proximity switch E 2.1 MS_22 "0"<br />

7 Receiver light curtain E 4.0 OSSD "1" "1" signal in case of free protection<br />

field<br />

8 Indicator light (yellow) A 10.0 ACTUATOR "0" Simulated machine<br />

9 Indicator light (white) A 10.1 MLAMP "0" Muting lamp<br />

No. Instruction Response<br />

A 10.0 A 10.1<br />

Note<br />

1 Press the push<br />

button E 0.1 and<br />

release it.<br />

"0" "0" Acknowledgement<br />

2 Press the push<br />

button E 0.0 and<br />

release it.<br />

3 Interrupt the protection<br />

field<br />

4 Repeat No. 1 and<br />

2<br />

"1" "0" Start of the<br />

"machine"<br />

"0" "0" OSSD="0"<br />

"1" "0" Start of the<br />

"machine"<br />

5 Set E 1.0 = "1" "1" "0" Muting sensor 11<br />

triggers<br />

Note<br />

No. Instruction Response<br />

A 10.0 A 10.1<br />

6 Set E 1.1 = "1"<br />

(this action has to<br />

be performed<br />

within DISCTIM1)<br />

7 Interrupt the protection<br />

field<br />

8 Wait until<br />

TIME_MAX has<br />

elapsed<br />

Note<br />

"1" "1" Start muting mode<br />

Protection field not<br />

active!<br />

"1" "1" –<br />

"0" "0" Muting not yet completed<br />

and<br />

t>TIME_MAX<br />

Functional Example No. AS-FE-I-005-V10-EN 225<br />