Connection of the LS4<br />

Integrating the LS4 into the PROFIBUS network requires the<br />

GSD file of the LS4. It is delivered with the LS4. Install the GSD<br />

into the hardware configuration of STEP 7 ( Menu Options -><br />

Install new GSD). Subsequently, the LS4 is available in the<br />

hardware catalog (within the hardware configuration of<br />

STEP 7, see following figure).<br />

Externally, the LS4 has five male/female connectors<br />

(X1, X2,...,X5).<br />

Connect these male/female connectors as follows:<br />

Male/<br />

female<br />

connector<br />

X1 Restart<br />

button<br />

Function Note/Explanation<br />

X2 PROFIBUS<br />

output<br />

X3 PROFIBUS<br />

input<br />

X4 Power supply Pin 1: +24V DC<br />

Pin 3: 0V DC<br />

X5 Optical PC<br />

interface<br />

(also referred<br />

to as PC<br />

adapter)<br />

X5<br />

X1 X2 X3 X4<br />

Here you connect a push button (NO)<br />

(considered in chapter 3 in the table<br />

"Hardware components"). This button has<br />

two functions:<br />

■ Unlocking the scanner-internal starting/restarting<br />

lockout, if it has been<br />

activated. In this example it has not<br />

been activated. However, a restarting<br />

lockout has been realized in the failsafe<br />

S7-program.<br />

■ Error acknowledgement, if the LS4 is in<br />

failure mode.<br />

If the LS4 is the last device at the PROFI-<br />

BUS, a standards compliant terminating<br />

resistor should be connected (this was the<br />

case in our test run).<br />

–<br />

Connected to the COM interface of the<br />

PG/PC on which the programming software<br />

LS4Soft has been installed.<br />

Note<br />

The cable outlet of the PC adapter at LS4 must point in the<br />

direction of the detection zone. The PC adapter should<br />

only be connected in the installation phase or for control<br />

purposes.<br />

Functional Example No. AS-FE-I-010-V11-EN 301<br />

G_FB_XX_183<br />

Ex. No.<br />

10