Ex. No.<br />

5<br />

Component Type MRPD / Ordering data Qty Manufacturer<br />

Terminal module for ET 200S TM-P15S23-A0 6ES7193-4CD20-0AA0 2 <strong>Siemens</strong> AG<br />

Terminal module for ET 200S TM-E15S24-A1 6ES7193-4CA20-0AA0 3<br />

Terminal module for ET 200S TM-E30C46-A1 6ES7193-4CF50-0AA0 2<br />

Profile rail 482.6 mm 6ES7390-1AE80-0AA0 1<br />

Standard mounting rail 35 mm, length: 483 mm 6ES5710-8MA11 1<br />

Indicator light incl. incandescent<br />

lamp<br />

white 3SB3217-6AA60 1<br />

Optional: Indicator light incl.<br />

incandescent lamp<br />

yellow 3SB3217-6AA30 1<br />

Optical proximity switch<br />

(as muting sensor)<br />

Diffuse sensor (type K80) 3RG7200-6CC00 4<br />

SIGUARD light curtain Cat. 4 Standard TRANSMITTER<br />

resolution 30 mm<br />

3RG7844-2SD03-0SS0 1<br />

SIGUARD light curtain Cat. 4 Standard RECEIVER<br />

resolution 30 mm<br />

3RG7844-2SD03-0SS1 1<br />

Hirschmann contact box incl. crimp contacts, even 3RG7848-2DA 2<br />

Push button green, 1NO 3SB3801-0DA3 2<br />

Note<br />

The functionality was tested with the hardware components<br />

listed. Similar products not included in the above<br />

list can also be used. Please note that in this case<br />

Configuration software/tools<br />

Setup and Wiring<br />

In order to set up and wire the functional example, it is absolutely<br />

necessary to consider the following note:<br />

Warning!<br />

In order to meet the requirements of <strong>Safety</strong> Category<br />

4, it is obligatory to read back the process signal to<br />

the actuator. Read back is not implemented in this<br />

example.<br />

The actuator in this example is an indicator light simulating<br />

a machine. If other actuators are used, read<br />

back has to be ensured by the user. The <strong>Safety</strong> <strong>Integrated</strong><br />

Functional Example AS-FE-I-007-V10-EN provides<br />

a detailed description of "Read back".<br />

222 Functional Example No. AS-FE-I-005-V10-EN<br />

changes in the sample code (e.g. different addresses)<br />

may become necessary.<br />

Component Type MRPD / Ordering data Qty Manufacturer<br />

SIMATIC STEP 7 V5.3 + SP1 6ES7810-4CC07-0YA5 1 <strong>Siemens</strong> AG<br />

SIMATIC Distributed <strong>Safety</strong> V5.3 6ES7833-1FC01-0YA5 1<br />

An overview of the hardware structure<br />

The arrangement to implement the light curtain with muting<br />

function consists of a PROFIBUS configuration. A failsafe S7-<br />

CPU is used as DP master, an ET 200S as DP slave. The yellow<br />

indicator light, which can be used optionally, simulates the<br />

hazardous "machine", the white indicator light indicates active<br />

muting.<br />

Note<br />

Except for the connected safety components, the Power<br />

supply (for the light curtain) must not supply any additional<br />

parts of the machine with power. Both power supplies<br />

require the same ground.<br />

Note<br />

A 4DI electronic module can also be used instead of two<br />

2DI electronic modules. The "high feature" electronic<br />

modules can also be replaced by standard modules.