SIMATIC Runtime System<br />

Function Block "F_DRIVE" for safe monitoring of drive functions<br />

The safety-related function block "F_DRIVE" requires the<br />

safety-related Distributed <strong>Safety</strong> System. The system manual<br />

<strong>Safety</strong> Engineering in SIMATIC S7" (s. Chapt. 2.2.1) provides a<br />

detailed description of this safety system.<br />

The function block "F_DRIVE" ensures safe monitoring of the<br />

drive functions and establishes safety-related communication<br />

between the SIMOTION/SINAMICS drive system and the failsafe<br />

Simatic CPU. A sin/cos encoder has to be connected to the<br />

SMx20 module issuing signals that will be evaluated.<br />

In the event of an error, safe drive standstill is activated via a<br />

F-DO thus bringing the drive into a safe operational state.<br />

The following safety functions can be implemented depending<br />

on the relevant application:<br />

■ Safe standstill<br />

■ Safe shutdown<br />

■ Safe operating stop<br />

■ Safely limited speed<br />

Caution<br />

Before inserting the fail-safe application block FB300<br />

"F_DRIVE", you have to copy the fail-safe blocks FB186<br />

"F_TOF", FC174 "F_SHL_W" and FC176 "F_BO_W" from<br />

the block container F-Application Blocks of the fail-safe<br />

Distributed <strong>Safety</strong> library (V1) into the block container<br />

of your S7 program (if not already done).<br />

The blocks must be assigned the above-mentioned<br />

numbers and may not be renumbered.<br />

Caution<br />

The block functions are only ensured by setting the relevant<br />

parameters in the hardware configuration.<br />

Caution<br />

A function test is required to check the block functions.<br />

Notice<br />

The fail-safe monitoring time and the fail-safe mode of<br />

the module are described analogously to the manual<br />

"<strong>Safety</strong> Engineering in SIMATIC S7 System Description"!<br />

Note<br />

The constants "VKE0" and "VKE1" must be used in the<br />

program block through fully qualified access to<br />

"F_GLOBDB". "VKE0" is reproduced by<br />

"F_GLOBDB".VKE0, "VKE1" by "F_GLOBDB".VKE1.<br />

They are used to permanently connect the inputs of<br />

the function block and may not be modified by the<br />

safety program.<br />

Function Example No. MC-FE-I-004-V11-EN 449<br />