ACK<br />

PS<br />

307<br />

START<br />

CPU<br />

315F<br />

Wiring of the hardware components<br />

Requirements: The power supplies are supplied with 230V AC.<br />

First check the addresses set at the hardware components<br />

listed below:<br />

Hardware<br />

component<br />

IM 151 High<br />

Feature<br />

DP<br />

Muting<br />

sensor 11<br />

IM 151<br />

HF<br />

Muting<br />

sensor 12<br />

PM-E<br />

Address<br />

to be set<br />

6 (PROFIBUS address)<br />

F-DI Switch position:<br />

1111111110<br />

F-DO Switch position:<br />

1111111100<br />

2DI<br />

HF<br />

PM-E<br />

Muting<br />

sensor 21<br />

Note<br />

F-DI<br />

F-DO<br />

Can be changed<br />

Simulated<br />

„Machine“<br />

Muting lamp<br />

Muting<br />

sensor 22<br />

RECEIVER<br />

Light<br />

curtain<br />

The PROFIsafe addresses are<br />

automatically assigned during<br />

configuring the failsafe<br />

modules in STEP 7. The<br />

PROFIsafe addresses 1 to<br />

1022 are permissible. Please<br />

make sure that the setting at<br />

the address switch (DIL<br />

switch) on the side of the<br />

module corresponds to the<br />

PROFIsafe address in the<br />

hardware configuration of<br />

STEP 7.<br />

Note<br />

The DP interface of the CPU 315F must be connected<br />

with the DP interface of the IM 151 HF.<br />

PS<br />

307<br />

Note<br />

The wiring of the hardware is illustrated below. In the<br />

following table, the hardware components occurring<br />

several times are numbered so they can be allocated in<br />

the subsequent wiring plan.<br />

IM 151<br />

HF<br />

AUX1<br />

4 8<br />

2 6<br />

3 7<br />

SENDER<br />

Light<br />

curtain A4 A8<br />

IM 151<br />

HF<br />

PM-E<br />

PM-E<br />

2DI<br />

HF<br />

2DI<br />

HF<br />

PM-E<br />

PM-E<br />

F-DI<br />

F-DI<br />

F-DO PM-E PM-E<br />

F-DO<br />

2 8<br />

3 7<br />

AUX1<br />

4 8<br />

2 6<br />

3 7<br />

Functional Example No. AS-FE-I-005-V10-EN 223<br />

A4<br />

A4<br />

2 DI HF<br />

1 5<br />

2 DI HF<br />

1 5<br />

2 8<br />

3 7<br />

A8<br />

A8<br />

A4<br />

A4<br />

2 DI HF<br />

1 5<br />

2 6<br />

3 7<br />

A8<br />

A8<br />

G_FB_XX_124<br />

G_FB_XX_125<br />

Ex. No.<br />

5