Function test<br />

After wiring the hardware components, you can check the inputs<br />

and outputs used with regard to their functionality (after<br />

downloading the S7 project).<br />

Inputs/outputs used<br />

The values listed in the "Signal (default value)" column refer to<br />

the following (error-free) state:<br />

■ Closed safety door<br />

■ Stoppage of a hazardous machine<br />

No. Hardware<br />

component<br />

1 Monitoring unlocking of<br />

the safety position switch<br />

(NO)<br />

Testing inputs and outputs<br />

Requirements: The inputs and outputs have the default values<br />

specified under "Inputs/outputs used".<br />

Adress Symbol Signal<br />

(default value)<br />

Note<br />

E 0.0 E_MAGNET "0" "0" signal if U=0 V at the magnet<br />

of the safety position<br />

switch<br />

2 Push button (NO) E 0.1 START "0" –<br />

3 Push button (NC) E 0.2 STOP "1" –<br />

4 Actuator contact in the<br />

E 2.0 SEP_ACT "1" Contact picking up the sepa-<br />

safety position switch (NC)<br />

rate actuator. "1" signal, if actuator<br />

in the safety position<br />

switch<br />

5 Hinge switch (NC) E 2.4 HINGED_SW "1" "1" signal, if door closed.<br />

6 Push button (NO) E 2.1 ACT_PAS "0" Simulates motion of a hazardous<br />

machine "0" means stoppage<br />

7 Magnet in the safety position<br />

switch<br />

A 8.0 COIL "0" "0": Door can be opened<br />

8 Indicator light A 8.1 ACTUATOR "0" Simulates hazardous machine<br />

No. Instruction Response<br />

A 8.0 A 8.1 Note<br />

1 None "0" "0" <strong>Safety</strong> door can be opened<br />

2 Press E 0.1<br />

and release<br />

3 Press E 0.2<br />

and release<br />

"1" "1" Pressing then holding E2.1<br />

(simulated movement).<br />

<strong>Safety</strong> door cannot be<br />

opened<br />

"1" "0" Keep E2.1 pressed (machine<br />

is switched off, however<br />

hazardous slowing down),<br />

<strong>Safety</strong> door cannot be<br />

opened<br />

4 Release E 2.1 "0" "0" Machine stoppage. <strong>Safety</strong><br />

door can be opened<br />

Functional Example No. AS-FE-I-003-V10-EN 197<br />