Ex. No.<br />

3.5<br />

Structure and wiring<br />

An overview of the hardware structure<br />

E-Stop Group 1<br />

Start<br />

PLC<br />

PROFIBUS DP<br />

1<br />

4<br />

-<br />

8<br />

2<br />

K<br />

T<br />

3<br />

Connecting-up the hardware components<br />

SPS<br />

M ast<br />

er<br />

IM<br />

151-1<br />

PROFIBUS<br />

DP<br />

PM-D<br />

FX1<br />

T M -PF<br />

30<br />

S47-G1<br />

IM 151<br />

PM -D FX1<br />

SF<br />

F-DS1e-x<br />

PWR SG 1 SG 2<br />

SG 4<br />

SG 5 SG 6<br />

1 2<br />

5 2<br />

1 2<br />

6 3<br />

3 1<br />

3 1<br />

2<br />

6<br />

2 T1 4 T2 6 T3<br />

1 L1 3 L2 5 L3<br />

Group 1<br />

F-DS1e-x<br />

2 T1 4 T2 6 T3<br />

66 Functional Example No. CD-FE-I-029-V10-EN<br />

F-DS1e-x<br />

2 T1 4 T2 6 T3<br />

Group 1.1<br />

F-DS1e-x<br />

SG1 SG1 SG2 SG2<br />

2 T1 4 T2 6 T3<br />

E-Stop Group 1.1<br />

Start<br />

Feeding<br />

ET200S with PM-D-FX1<br />

and Motorstarter Failsafe<br />

S7-300 A1 A2 A3 A4 A5 K1<br />

F-DS1e-x<br />

=SG1<br />

Group 1<br />

F-DS1e-x<br />

=SG1<br />

Group 1.1<br />

F-DS1e-x<br />

=SG2<br />

F-DS1e-x<br />

=SG2<br />

Terminating module<br />

1<br />

4<br />

-<br />

8<br />

2<br />

K<br />

T<br />

3<br />

3TK2841<br />

K2<br />

3T K2 84 1<br />

Additional motor starters can be inserted in an ET 200S Station.<br />

These are assigned to a group and can be shutdown by<br />

actuating the appropriate EMERGENCY STOP command device.<br />

A0 1<br />

8<br />

A1 15<br />

22 SG1<br />

1 K1 Y32<br />

Y35 EIN 13<br />

1 K2 Y32<br />

Y35 EIN 13<br />

2<br />

16<br />

A1 Y34<br />

14<br />

A1 Y34<br />

14<br />

9<br />

23 SG2<br />

18<br />

25 SG3<br />

A2<br />

Y11<br />

Y21<br />

NOT-HALT<br />

11 21<br />

A2<br />

Y11<br />

Y21<br />

NOT-HALT<br />

11 21<br />

19<br />

26 SG4<br />

Y22<br />

Y12<br />

12 22<br />

Y22<br />

Y12<br />

12 22<br />

L+<br />

U2 ext.<br />

M<br />

1L+<br />

2L+<br />

1M<br />

2M<br />

6<br />

L+<br />

13<br />

U1 ext.<br />

7<br />

M<br />

14<br />

20<br />

27 SG5<br />

21<br />

28 SG6<br />

14<br />

24<br />

14<br />

24<br />

Make sure the wiring is cross-proof!