Ex. No.<br />

4<br />

6. Axis communication startup<br />

The redundant coarse position information has to be connected<br />

to the PROFIBUS and transferred to SIMOTION as follows:<br />

P2061.x = r484<br />

The redundant coarse position information is required as a<br />

double word.<br />

7. Axis communication startup<br />

The encoder status word has to be connected to the encoder<br />

to be monitored (if not already done in the standard configuration):<br />

P2051.x = r481<br />

The coarse position information is only required as a word.<br />

8. Control Unit (CU) startup<br />

The sign of life signal is transferred via the Control Unit (see<br />

Chapt. 6.4). That means, one transmit and receive word must<br />

be configured for each axis<br />

e.g. P2051.x = r2050.x<br />

Note<br />

The communication configuration in the HW Config<br />

must be extended by the additional transmit and receive<br />

words.<br />

446 Function Example No. MC-FE-I-004-V11-EN