09.02.2018 Views

Practical Guige to Free Energy Devices

eBook 3000 pages! author: Patrick J. Kelly "This eBook contains most of what I have learned about this subject after researching it for a number of years. I am not trying to sell you anything, nor am I trying to convince you of anything. When I started looking into this subject, there was very little useful information and any that was around was buried deep in incomprehensible patents and documents. My purpose here is to make it easier for you to locate and understand some of the relevant material now available. What you believe is up to yourself and is none of my business. Let me stress that almost all of the devices discussed in the following pages, are devices which I have not personally built and tested. It would take several lifetimes to do that and it would not be in any way a practical option. Consequently, although I believe everything said is fully accurate and correct, you should treat everything as being “hearsay” or opinion. Some time ago, it was commonly believed that the world was flat and rested on the backs of four elephants and that when earthquakes shook the ground, it was the elephants getting restless. If you want to believe that, you are fully at liberty to do so, however, you can count me out as I don’t believe that. " THE MATERIAL PRESENTED IS FOR INFORMATION PURPOSES ONLY. SHOULD YOU DECIDE TO PERFORM EXPERIMENTS OR CONSTRUCT ANY DEVICE, YOU DO SO WHOLLY ON YOUR OWN RESPONSIBILITY -- NEITHER THE COMPANY HOSTING THIS WEB SITE, NOR THE SITE DESIGNER ARE IN ANY WAY RESPONSIBLE FOR YOUR ACTIONS OR ANY RESULTING LOSS OR DAMAGE OF ANY DESCRIPTION, SHOULD ANY OCCUR AS A RESULT OF WHAT YOU DO. ​

eBook 3000 pages!
author: Patrick J. Kelly

"This eBook contains most of what I have learned about this subject after researching it for a number of years. I am not trying to sell you anything, nor am I trying to convince you of anything. When I started looking into this subject, there was very little useful information and any that was around was buried deep in incomprehensible patents and documents. My purpose here is to make it easier for you to locate and understand some of the relevant material now available. What you believe is up to yourself and is none of my business. Let me stress that almost all of the devices discussed in the following pages, are devices which I have not personally built and tested. It would take several lifetimes to do that and it would not be in any way a practical option. Consequently, although I believe everything said is fully accurate and correct, you should treat everything as being “hearsay” or opinion.

Some time ago, it was commonly believed that the world was flat and rested on the backs of four elephants and that when earthquakes shook the ground, it was the elephants getting restless. If you want to believe that, you are fully at liberty to do so, however, you can count me out as I don’t believe that. "

THE MATERIAL PRESENTED IS FOR INFORMATION PURPOSES ONLY. SHOULD YOU DECIDE TO PERFORM EXPERIMENTS OR CONSTRUCT ANY DEVICE, YOU DO SO WHOLLY ON YOUR OWN RESPONSIBILITY -- NEITHER THE COMPANY HOSTING THIS WEB SITE, NOR THE SITE DESIGNER ARE IN ANY WAY RESPONSIBLE FOR YOUR ACTIONS OR ANY RESULTING LOSS OR DAMAGE OF ANY DESCRIPTION, SHOULD ANY OCCUR AS A RESULT OF WHAT YOU DO.

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Fig.7 shows a graphical representation of input voltage versus input current for a coil resistance of 6.8 ohms and<br />

for a four pole ro<strong>to</strong>r which is 230 mm in diameter. The exact timing sequence for switching coils on and off will<br />

vary depending on the parameters of the rotary device and the controller. Accordingly by varying the input<br />

voltage, coil resistance and overall impedance of the input circuit for each coil the duration during which a coil<br />

must be turned on will change. In fact, there are many fac<strong>to</strong>rs which can change the timing sequence of switching<br />

the coils on, and some of these are summarised below:<br />

The Sta<strong>to</strong>r<br />

The variables include the choice of material used in constructing the sta<strong>to</strong>r iron core, the number of sta<strong>to</strong>r iron<br />

cores and their positioning as well as the physical size, section area and shape of the sta<strong>to</strong>r iron cores.<br />

Ro<strong>to</strong>r<br />

The physical size and magnetic strength and shape of the polarised permanent magnetic body as contained in the<br />

ro<strong>to</strong>r, the number of polarised permanent magnetised bodies being contained in the ro<strong>to</strong>r, the positioning and<br />

spacing of the same, the use of all like polarities of permanent magnetic bodies or the use of alternating polarities<br />

for the permanent magnetic bodies.<br />

Sta<strong>to</strong>r Coil<br />

The physical size of the coils being positioned on <strong>to</strong> the sta<strong>to</strong>r iron core, the type of wire used <strong>to</strong> wind the coils,<br />

such as copper, silver, aluminium or others. The shape and cross-sectional areas of the winding wire, such as<br />

round, square, triangular, rectangular and others; the number of turns and layers wound on <strong>to</strong> the coil and<br />

consequent ohms resistance; the method of winding on <strong>to</strong> a coil holder, single winding, double winding, double<br />

winding same direction, double winding opposite direction, left <strong>to</strong> right or right <strong>to</strong> left, interwoven winding, whether<br />

the above examples would be wound on <strong>to</strong> a single coil holder.<br />

Speed of Ro<strong>to</strong>r<br />

This can be controlled by the length of the directed (input) DC current (on and cut-off period) and/or the control of<br />

the supply voltage used <strong>to</strong> supply the sta<strong>to</strong>r coils.<br />

Other variations that may be made <strong>to</strong> the system include the following:<br />

a. The coils can be connected in series, parallel, or series parallel.<br />

b. It is only when the north/south arrangements of the permanent magnets are used in the ro<strong>to</strong>r that even<br />

numbers of permanent magnets are necessary, but not necessarily even numbers of pairs of sta<strong>to</strong>r coils<br />

positioned in the sta<strong>to</strong>r. Furthermore the direction DC current Supplied <strong>to</strong> the sta<strong>to</strong>r coils in the north south<br />

arrangement above must be synchronised, meaning that the magnetic field as needed in the sta<strong>to</strong>r coil(s)<br />

must be of corresponding polarity <strong>to</strong> the sta<strong>to</strong>r coil(s), iron core end, which faces the permanent magnets.<br />

2 - 45