09.02.2018 Views

Practical Guige to Free Energy Devices

eBook 3000 pages! author: Patrick J. Kelly "This eBook contains most of what I have learned about this subject after researching it for a number of years. I am not trying to sell you anything, nor am I trying to convince you of anything. When I started looking into this subject, there was very little useful information and any that was around was buried deep in incomprehensible patents and documents. My purpose here is to make it easier for you to locate and understand some of the relevant material now available. What you believe is up to yourself and is none of my business. Let me stress that almost all of the devices discussed in the following pages, are devices which I have not personally built and tested. It would take several lifetimes to do that and it would not be in any way a practical option. Consequently, although I believe everything said is fully accurate and correct, you should treat everything as being “hearsay” or opinion. Some time ago, it was commonly believed that the world was flat and rested on the backs of four elephants and that when earthquakes shook the ground, it was the elephants getting restless. If you want to believe that, you are fully at liberty to do so, however, you can count me out as I don’t believe that. " THE MATERIAL PRESENTED IS FOR INFORMATION PURPOSES ONLY. SHOULD YOU DECIDE TO PERFORM EXPERIMENTS OR CONSTRUCT ANY DEVICE, YOU DO SO WHOLLY ON YOUR OWN RESPONSIBILITY -- NEITHER THE COMPANY HOSTING THIS WEB SITE, NOR THE SITE DESIGNER ARE IN ANY WAY RESPONSIBLE FOR YOUR ACTIONS OR ANY RESULTING LOSS OR DAMAGE OF ANY DESCRIPTION, SHOULD ANY OCCUR AS A RESULT OF WHAT YOU DO. ​

eBook 3000 pages!
author: Patrick J. Kelly

"This eBook contains most of what I have learned about this subject after researching it for a number of years. I am not trying to sell you anything, nor am I trying to convince you of anything. When I started looking into this subject, there was very little useful information and any that was around was buried deep in incomprehensible patents and documents. My purpose here is to make it easier for you to locate and understand some of the relevant material now available. What you believe is up to yourself and is none of my business. Let me stress that almost all of the devices discussed in the following pages, are devices which I have not personally built and tested. It would take several lifetimes to do that and it would not be in any way a practical option. Consequently, although I believe everything said is fully accurate and correct, you should treat everything as being “hearsay” or opinion.

Some time ago, it was commonly believed that the world was flat and rested on the backs of four elephants and that when earthquakes shook the ground, it was the elephants getting restless. If you want to believe that, you are fully at liberty to do so, however, you can count me out as I don’t believe that. "

THE MATERIAL PRESENTED IS FOR INFORMATION PURPOSES ONLY. SHOULD YOU DECIDE TO PERFORM EXPERIMENTS OR CONSTRUCT ANY DEVICE, YOU DO SO WHOLLY ON YOUR OWN RESPONSIBILITY -- NEITHER THE COMPANY HOSTING THIS WEB SITE, NOR THE SITE DESIGNER ARE IN ANY WAY RESPONSIBLE FOR YOUR ACTIONS OR ANY RESULTING LOSS OR DAMAGE OF ANY DESCRIPTION, SHOULD ANY OCCUR AS A RESULT OF WHAT YOU DO.

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Referring <strong>to</strong> Fig.2, the permanent magnet 24 is shown having seven coils 26-38 mounted flat on its upper surface.<br />

Seven coils are shown, and the coils 26-38 have electrical connections made through plate 12 <strong>to</strong> other circuit<br />

members which will be described later in connection with Fig.13. Another member 40 is mounted on the upper<br />

surface of the lower plate 14 and a similar member 42 is mounted on the underside of the plate 12.<br />

A shaft 44, (shown oriented vertically for convenience) extends through aligned holes in the members 42, 12 and<br />

24. The lower end of shaft 44 is connected <strong>to</strong> disk 46 which has a pair of curved openings 48 and 50 shown<br />

diametrically opposite <strong>to</strong> each other, a little in from the edge of disc 46. The purpose of these openings 48 and 50<br />

will be explained later on.<br />

Shaft 44 is also connected <strong>to</strong> another disc 52 which is located on the shaft so as <strong>to</strong> be positioned adjacent <strong>to</strong> the<br />

coils 26-38. Disc 52 has a pair of permanent magnets 54 and 56 mounted on or in it positioned diametrically<br />

opposite <strong>to</strong> each other. Magnets 54 and 56 have their north and south poles oriented as shown in Fig.2, that is<br />

with north poles shown on their lower sides and their south poles on the upper sides. This is done so that there<br />

will be mutual magnetic attraction and coupling between the magnets 54 and 56 and the fixed magnet 24. The<br />

polarity of the magnets 54 and 56 and/or of the magnet 24 can also be reversed if desired for some purposes <strong>to</strong><br />

produce relative magnetic repulsion between them.<br />

Referring again <strong>to</strong> Fig.2, the lower plate 40 is shown having a series of pho<strong>to</strong>transis<strong>to</strong>rs 58-70 mounted on its<br />

upper surface and spaced out as shown. These pho<strong>to</strong>transis<strong>to</strong>rs are positioned under the centres of the coils 26-<br />

38 which are mounted on magnet 24. An equal number of infra red emitters 72-84 are mounted on the under<br />

surface of the member 42 aligned with the pho<strong>to</strong>transis<strong>to</strong>rs. There are seven infra red emitters 72-84 shown,<br />

each of which is in alignment with a respective one of the seven pho<strong>to</strong>transis<strong>to</strong>rs 58-70 and with one of the seven<br />

coils 26-38. This arrangement is such that when the shaft 44 and the components attached <strong>to</strong> it, including discs<br />

46 and 52, rotate relative <strong>to</strong> the other members including magnet 24, the curved openings 48 and 50 pass under<br />

the infra red emitters and cause the pho<strong>to</strong>transis<strong>to</strong>rs <strong>to</strong> switch on for a predetermined time interval. This<br />

establishes a sequence of energised circuits which powers coils 26-38, one at a time, which in turn, causes a<br />

momentary interruption of the magnetic interaction between one of the permanent magnets 54 and 56 and<br />

magnet 24.<br />

When a coil is mounted on <strong>to</strong>p of a permanent magnet such as permanent magnet 24 and energised it acts <strong>to</strong><br />

concentrate the flux in a symmetrical magnetic field resulting in a non-symmetrical field when another permanent<br />

magnet is above the coil on magnet 24. This results in uneven or non-uniform forces being produced when the<br />

coil is energised and this causes a <strong>to</strong>rque between the two permanent magnets, which tries <strong>to</strong> move one of the<br />

permanent magnets relative <strong>to</strong> the other.<br />

Fig.3 shows the position when one of the magnets 54 is located immediately above one of the coils, say, coil 26.<br />

In this position there would be magnetic coupling between the magnets 54 and 24 so long as there is no voltage<br />

across the coil 26. However, if a voltage is placed across the coil 26 it will interrupt the magnetic coupling<br />

between the magnets 54 and 24 where the coil is located. This means that if there is any <strong>to</strong>rque developed, it will<br />

be developed <strong>to</strong> either side of the coil 26. Without energising the coil 26 there will be full attraction between the<br />

magnets 24 and 54 and no rotational force will be produced.<br />

A - 1005

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!