eBook 3000 pages! author: Patrick J. Kelly "This eBook contains most of what I have learned about this subject after researching it for a number of years. I am not trying to sell you anything, nor am I trying to convince you of anything. When I started looking into this subject, there was very little useful information and any that was around was buried deep in incomprehensible patents and documents. My purpose here is to make it easier for you to locate and understand some of the relevant material now available. What you believe is up to yourself and is none of my business. Let me stress that almost all of the devices discussed in the following pages, are devices which I have not personally built and tested. It would take several lifetimes to do that and it would not be in any way a practical option. Consequently, although I believe everything said is fully accurate and correct, you should treat everything as being “hearsay” or opinion. Some time ago, it was commonly believed that the world was flat and rested on the backs of four elephants and that when earthquakes shook the ground, it was the elephants getting restless. If you want to believe that, you are fully at liberty to do so, however, you can count me out as I don’t believe that. " THE MATERIAL PRESENTED IS FOR INFORMATION PURPOSES ONLY. SHOULD YOU DECIDE TO PERFORM EXPERIMENTS OR CONSTRUCT ANY DEVICE, YOU DO SO WHOLLY ON YOUR OWN RESPONSIBILITY -- NEITHER THE COMPANY HOSTING THIS WEB SITE, NOR THE SITE DESIGNER ARE IN ANY WAY RESPONSIBLE FOR YOUR ACTIONS OR ANY RESULTING LOSS OR DAMAGE OF ANY DESCRIPTION, SHOULD ANY OCCUR AS A RESULT OF WHAT YOU DO. ​

eBook 3000 pages!
author: Patrick J. Kelly

"This eBook contains most of what I have learned about this subject after researching it for a number of years. I am not trying to sell you anything, nor am I trying to convince you of anything. When I started looking into this subject, there was very little useful information and any that was around was buried deep in incomprehensible patents and documents. My purpose here is to make it easier for you to locate and understand some of the relevant material now available. What you believe is up to yourself and is none of my business. Let me stress that almost all of the devices discussed in the following pages, are devices which I have not personally built and tested. It would take several lifetimes to do that and it would not be in any way a practical option. Consequently, although I believe everything said is fully accurate and correct, you should treat everything as being “hearsay” or opinion.

Some time ago, it was commonly believed that the world was flat and rested on the backs of four elephants and that when earthquakes shook the ground, it was the elephants getting restless. If you want to believe that, you are fully at liberty to do so, however, you can count me out as I don’t believe that. "

THE MATERIAL PRESENTED IS FOR INFORMATION PURPOSES ONLY. SHOULD YOU DECIDE TO PERFORM EXPERIMENTS OR CONSTRUCT ANY DEVICE, YOU DO SO WHOLLY ON YOUR OWN RESPONSIBILITY -- NEITHER THE COMPANY HOSTING THIS WEB SITE, NOR THE SITE DESIGNER ARE IN ANY WAY RESPONSIBLE FOR YOUR ACTIONS OR ANY RESULTING LOSS OR DAMAGE OF ANY DESCRIPTION, SHOULD ANY OCCUR AS A RESULT OF WHAT YOU DO.

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

In its simplest form a two path permanent magnet control component only requires one control coil positioned<br />

along one of the control paths <strong>to</strong> permit the magnetic flux of a permanent magnet <strong>to</strong> be switched between the two<br />

paths. In particular, a side view of such a two path component 210 is shown in Fig.10G and includes a<br />

permanent magnet 211 pole pieces 212 and 213, and control coil 214 which may be connected <strong>to</strong> a suitable<br />

control circuit. By alternating energising control coil 214 in an opposing manner and an aiding manner the<br />

magnetic flux of permanent magnet can be switched between the path including armature 215 and the path<br />

including armature 216. When control coil 214 is energised in an opposing manner the magnetic flux will traverse<br />

the path including armature 215 and when control coil 214 is energised in an aiding manner the magnetic flux will<br />

traverse the path including armature 216. Control coil 214 could also be placed at any of the positions 217, 218,<br />

or 219 <strong>to</strong> achieve the flux path switching.<br />

Further, in the two coils embodiment shown in Fig.10H control coil 217 is added. In such a device, flux switching<br />

can be achieved by simultaneously energising control coil 214 in a flux aiding manner and control coil 217 in a flux<br />

opposing manner, and by then simultaneously reversing the energisation of the respective control coils 214 and<br />

217.<br />

Reference is made <strong>to</strong> Figs.11A-11F which depict devices similar <strong>to</strong> that of Figs.5-6 except that a bypass, formed<br />

of magnetic material, is provided in each case. In device 220 of Figs.11A-11C a bypass 222 is provided from<br />

pole piece 224 <strong>to</strong> pole piece 226 and is located between permanent magnet 228 and control coils 230, 232, with<br />

armature 234 located adjacent the ends of pole pieces 224, 226. In Fig.11A with no coil energisation, magnet<br />

flux components 236 and 237 travel as shown.<br />

When coils 230 and 232 are energised in an aiding or adding manner as in Fig.11B, the result is permanent<br />

magnet magnetic flux components 236 and 237 travelling as shown, and with the added magnetic flux component<br />