09.02.2018 Views

Practical Guige to Free Energy Devices

eBook 3000 pages! author: Patrick J. Kelly "This eBook contains most of what I have learned about this subject after researching it for a number of years. I am not trying to sell you anything, nor am I trying to convince you of anything. When I started looking into this subject, there was very little useful information and any that was around was buried deep in incomprehensible patents and documents. My purpose here is to make it easier for you to locate and understand some of the relevant material now available. What you believe is up to yourself and is none of my business. Let me stress that almost all of the devices discussed in the following pages, are devices which I have not personally built and tested. It would take several lifetimes to do that and it would not be in any way a practical option. Consequently, although I believe everything said is fully accurate and correct, you should treat everything as being “hearsay” or opinion. Some time ago, it was commonly believed that the world was flat and rested on the backs of four elephants and that when earthquakes shook the ground, it was the elephants getting restless. If you want to believe that, you are fully at liberty to do so, however, you can count me out as I don’t believe that. " THE MATERIAL PRESENTED IS FOR INFORMATION PURPOSES ONLY. SHOULD YOU DECIDE TO PERFORM EXPERIMENTS OR CONSTRUCT ANY DEVICE, YOU DO SO WHOLLY ON YOUR OWN RESPONSIBILITY -- NEITHER THE COMPANY HOSTING THIS WEB SITE, NOR THE SITE DESIGNER ARE IN ANY WAY RESPONSIBLE FOR YOUR ACTIONS OR ANY RESULTING LOSS OR DAMAGE OF ANY DESCRIPTION, SHOULD ANY OCCUR AS A RESULT OF WHAT YOU DO. ​

eBook 3000 pages!
author: Patrick J. Kelly

"This eBook contains most of what I have learned about this subject after researching it for a number of years. I am not trying to sell you anything, nor am I trying to convince you of anything. When I started looking into this subject, there was very little useful information and any that was around was buried deep in incomprehensible patents and documents. My purpose here is to make it easier for you to locate and understand some of the relevant material now available. What you believe is up to yourself and is none of my business. Let me stress that almost all of the devices discussed in the following pages, are devices which I have not personally built and tested. It would take several lifetimes to do that and it would not be in any way a practical option. Consequently, although I believe everything said is fully accurate and correct, you should treat everything as being “hearsay” or opinion.

Some time ago, it was commonly believed that the world was flat and rested on the backs of four elephants and that when earthquakes shook the ground, it was the elephants getting restless. If you want to believe that, you are fully at liberty to do so, however, you can count me out as I don’t believe that. "

THE MATERIAL PRESENTED IS FOR INFORMATION PURPOSES ONLY. SHOULD YOU DECIDE TO PERFORM EXPERIMENTS OR CONSTRUCT ANY DEVICE, YOU DO SO WHOLLY ON YOUR OWN RESPONSIBILITY -- NEITHER THE COMPANY HOSTING THIS WEB SITE, NOR THE SITE DESIGNER ARE IN ANY WAY RESPONSIBLE FOR YOUR ACTIONS OR ANY RESULTING LOSS OR DAMAGE OF ANY DESCRIPTION, SHOULD ANY OCCUR AS A RESULT OF WHAT YOU DO.

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

chamber signals that the precise, proper quantity of helium has been allowed <strong>to</strong> enter. The entry of helium is then<br />

immediately halted by the closing of valve V3.<br />

The next step in preparing the fuel is <strong>to</strong> add neon <strong>to</strong> the mixture. The potential on the relevant ionisation heads,<br />

particularly head 241 (see Fig.17C), is raised by the addition of approximately 26% which results in a <strong>to</strong>tal of<br />

approximately 62% of the <strong>to</strong>tal calculated potential and valve V31 is opened, thereby allowing neon <strong>to</strong> slowly enter<br />

the mixer via port 245. This gas passes through branch B36, ionisation head 241, and branch B35 directly in<strong>to</strong><br />

the mixing chamber. Since the previously admitted helium is fully charged, the neon absorbs all of the increased<br />

ionisation potential. As soon as the neon acquires the additional charge, a spectroscopic flash of light occurs and<br />

the opera<strong>to</strong>r closes valve V31.<br />

In the same manner, the potential on the ionisation heads is increased by the addition of approximately 17% for a<br />

<strong>to</strong>tal of approximately 79% of the <strong>to</strong>tal calculated potential and then valve V30 is opened <strong>to</strong> admit argon in<strong>to</strong> the<br />

mixer via port 243. This gas passes through branch B34, ionisation head 239, and branch B33 in<strong>to</strong> mixing<br />

chamber 261. Again, when the proper amount of argon has been admitted, it emits a spectroscopic flash of light<br />

and the opera<strong>to</strong>r closes valve V30. Next, the potential on the ionisation heads is increased by the addition of<br />

approximately 13% <strong>to</strong> result in a <strong>to</strong>tal of approximately 92% of the <strong>to</strong>tal calculated potential and valve V58 (see<br />

Fig.17D) is opened <strong>to</strong> admit kryp<strong>to</strong>n in<strong>to</strong> the system. The kryp<strong>to</strong>n gas passes through branch B51, ionisation<br />

head 271 and branch B48 in<strong>to</strong> chamber 261. Upon the emission of a spectroscopic flash of light by the gas, the<br />

opera<strong>to</strong>r closes valve V58. Finally, the potential on the ionisation heads is increased by the addition of<br />

approximately 8% which brings the ionisation potential <strong>to</strong> the full 100% of the calculated ionisation voltage and<br />

valve V56 is opened <strong>to</strong> admit xenon in<strong>to</strong> the mixer via port 279. This gas passes through branch B50, ionisation<br />

head 273 and branch B47 <strong>to</strong> the mixing chamber. When the proper amount of gas has been admitted, a<br />

spectroscopic flash of light occurs signalling the opera<strong>to</strong>r <strong>to</strong> close valve V56. Note that there are two<br />

filter/absorber units, labelled 253 and 291. Unit 253 is connected <strong>to</strong> the neon and argon inlet branches B33 and<br />

B35 while unit 291 is connected <strong>to</strong> the kryp<strong>to</strong>n and xenon inlet branches B47 and B48. These two units absorb<br />

hydrogen residue and immobilise the water vapour created when the pump circulates the gases and generates<br />

vacuum states.<br />

After all the gases are admitted in the desired proportions, all the valves are closed. (The mixture in the mixing<br />

chamber and in the adjacent tubing is at one atmosphere pressure at this time). Once this is done, the interval<br />

valves of the system are all opened (but the inlet and outlet valves remain closed) <strong>to</strong> allow the mixture <strong>to</strong> circulate<br />

throughout the tubing as follows: branch B44, magnetic coils 267 and 269, ionisation head 240, branch B29,<br />

ionisation head 231, branch B24, ionisation head 219, pump 217, branches B15 and B39A, ionisation gauge 255,<br />

branches B38 and B42, ionisation head 275, branch B28, ionisation head 229, non-directed cathode ray tube<br />

227, quadruple magnetic coil 272, ionisation head 221, branch B23, twin parallel magnetic coil 266, branch B25<br />

and mixing chamber 261. When this circuit is initially opened, the pressure of the mixture drops 40-50% because<br />

some of the tubing had previously been under vacuum. Pump 217 is then started <strong>to</strong> cause the gases <strong>to</strong> be slowly<br />

and evenly mixed.<br />

Because of dead space in the tubing and the reaction time of the opera<strong>to</strong>r, it may occur that the proportions of the<br />

gases are not exactly those set forth above. This is remedied during the circulation step. As the gas flows<br />

through ionisation gauge 255, excess gas is removed from the mixture so that the correct proportions are<br />

obtained. To do this the grid of gauge 255 is subjected <strong>to</strong> 100% ionisation energy and is heated <strong>to</strong> approximately<br />

165 degrees F. This temperature of 165 degrees F is related <strong>to</strong> xenon's boiling point of -165 degrees F in<br />

magnitude but is opposite in sign. Xenon is the heaviest of the five inert gases in the mixture. As the gas mixture<br />

flows through ionisation gauge 255, the gas a<strong>to</strong>ms that are in excess of their prescribed percentages are burned<br />

out of the mixture and their charge is acquired by the remaining gas a<strong>to</strong>ms from the grid of the ionisation gauge.<br />

Because the gases are under a partial vacuum, the ionisation gauge is able <strong>to</strong> adjust the gas percentages very<br />

precisely. (Note: The steps described in the last two paragraphs are repeated if the finished gases are rejected in<br />

the final quality control step described below).<br />

The next step involves purifying the mixture so that only the five inert gases remain, absorbing any free electrons<br />

and regulating the electrical charge in the mixture. To do this, the circuit consisting of the following components is<br />

opened: Branch B44, magnetic coil 267, magnetic coil 269, ionisation head 240, branch B29, ionisation head 231,<br />

branch B24, ionisation head 219, pump 217, branches B15 and B39, magnetic coil 287 (see Fig.17D) polariser<br />

289, branch B17, ionising and filtering unit 215, branches B16, B42, and B41, x-ray tube 263, branch B21,<br />

ionisation head 221, branch B23, magnetic coil 266, branch B25, and mixing chamber 261. The gases should<br />

complete this circuit at least three times.<br />

The last step required <strong>to</strong> prepare the mixture for bottling is polarisation of the argon. The circuit required <strong>to</strong> do this<br />

consists of the following components: mixing chamber 261, branch B44, magnetic coil 267, magnetic coil 269,<br />

ionisation head 240, cathode ray tube 265, branch B40, tubing coil 257, branches B49 and B30, ionisation head<br />

231, branch B24, ionisation head 219, pump 217, branches B15 and B39, twin parallel magnetic coil 287 (see<br />

A - 1184

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!