o-TOLUIDINE CAS N°: 95-53-4 - UNEP Chemicals
o-TOLUIDINE CAS N°: 95-53-4 - UNEP Chemicals
o-TOLUIDINE CAS N°: 95-53-4 - UNEP Chemicals
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
OECD SIDS o-<strong>TOLUIDINE</strong><br />
5. TOXICITY ID: <strong>95</strong>-<strong>53</strong>-4<br />
DATE: 07.01.2005<br />
188<br />
GLP : no data<br />
Test substance : other TS: see freetext TC<br />
Test condition : This study is part of a International Collaborative Program, published as:<br />
Evaluation of Short-Term Tests for Cancerogens Progress in Mutation<br />
Research Vol 1. Edited by Frederick J. Serres and John Ashby, 1981<br />
CHEMICALS:<br />
42 coded chemicals were investigated in short-term tests for<br />
cancerogenicity in different laboratories<br />
It should be suggested that only 100%-pure chemicals should be used<br />
when evaluating a test system.<br />
---In the present work the compound with code no 41 is declared as otoluidine<br />
hydrochloride, whereas in an the overall summary of this program<br />
code no. 41 is declared as o-toluidine.<br />
METABOLIC ACTIVATION:<br />
three levels (4, 10 and 30% by volume) of S9 mix - liver homogenates from<br />
with Aroclor 1254 induced male Wistar rats<br />
Reliability : (4) not assignable<br />
Method-Evaluation, only two Salmonella strains tested, no data on negative<br />
controls, no data on cytotoxicity, no single data on results, unclear use: otoluidine<br />
or o-toluidine hydrochloride<br />
15.07.2004 (152) (223)<br />
Type : Bacterial reverse mutation assay<br />
System of testing : Salmonella typhimurium<br />
Test concentration : up to 1000 µg/ml<br />
Cycotoxic concentr. : no data<br />
Metabolic activation : with<br />
Result : negative<br />
Method : other: Mutascreen automated system for bacterial mutagenicity tests<br />
Year : 1985<br />
GLP : no data<br />
Test substance : other TS: o-toluidine, no data on purity<br />
Remark : Evaluation of an automated test system "Mutascreen"<br />
Reliability : (4) not assignable<br />
Documentation insufficient for assessment,<br />
Evaluation of an automated test system<br />
15.07.2004 (224)<br />
Type : Bacterial reverse mutation assay<br />
System of testing : Salmonella typhimurium TA 98, TA 100; Escherichia coli WP2uvrA<br />
Test concentration :<br />
Cycotoxic concentr. :<br />
Metabolic activation : with<br />
Result : negative<br />
Method : other: Mutascreen automated system for bacterial mutagenicity tests<br />
Year : 1985<br />
GLP : no data<br />
Test substance : other TS: o-toluidine hydrochloride<br />
Remark : Evaluation of an automated test system "Mutascreen"<br />
Reliability : (4) not assignable<br />
Documentation insufficient for assessment,<br />
Evaluation of an automated test system<br />
15.07.2004 (225)<br />
Type : Salmonella typhimurium reverse mutation assay<br />
<strong>UNEP</strong> PUBLICATIONS