MECON LIMITED<br />

REGD. OFF : RANCHI (BIHAR)<br />

c:\fateh\standard\stad-eqp.wp<br />

PROCESS & PIPING<br />

DESIGN SECTION<br />

NEW DELHI<br />

STANDARD SPECIFICATION<br />

TITLE Hydrostatic Testing <strong>of</strong> Onshore Cross- SPECIFICATION NO. PAGE 14 OF 17<br />

country Pipelines<br />

MEC/S/05/62/03 REVISION A<br />

Further the temperature measurement shall be taken :<br />

- during the filling operation<br />

- during the thermal stabilization stage<br />

- during the hydrostatic test<br />

The thermocouple’s sensitivity shall enable temperature readings with an accuracy <strong>of</strong><br />

±0.2°C.<br />

b) Water temperature shall also be measured on the pump delivery by means <strong>of</strong> a<br />

recording thermometer (temperature recorder) throughout the filling stage.<br />

The recording thermometer shall have the following features :<br />

Accuracy ± 1% <strong>of</strong> the scale range<br />

Scale - 10° to + 40° C<br />

Recording: Continuous on tape or disk, diagram within 100mm<br />

Feed : 20mm/h for tape diagrams, 7.5°/h for disk diagrams.<br />

c) Ground temperature shall be taken by measuring pipe temperature at the<br />

thermocouple prior to starting the filling operation.<br />

d) Environmental temperature shall be recorded from the beginning <strong>of</strong><br />

pressurization to the end <strong>of</strong> the test by means <strong>of</strong> a recording thermometer<br />

featuring the following characteristics:<br />

Accuracy ± 1% <strong>of</strong> the scale range<br />

Scale - 0° to + 60° C<br />

Recording: Continuous on tape or disk, diagram width 100mm<br />

Feed : 20mm/h for tape diagrams, 7.5°/h for disk diagrams.