MECON LIMITED<br />

Delhi<br />

PROCESS & PIPING<br />

DESIGN SECTION<br />

TECHNICAL SPECIFICATION FOR<br />

TEMPORARY CATHODIC<br />

PROTECTION SYSTEM<br />

TECHNICAL SPECIFICATION NO. : MEC/TS/05/62/016A REV-1 Page 4 <strong>of</strong> 19<br />

4.1 Protection current density<br />

(i) Pipe lines having polyethylene coatings<br />

Pipeline<br />

Protection current density*<br />

surrounding Temporary CP Permanent CP<br />

(µA/m²)<br />

(MA/m²)<br />

Normal soil 50 0.120<br />

Marshy area/<br />

100 0.120<br />

buried in sea<br />

water/<br />

crossing<br />

HDD<br />

High resistivity<br />

25 100<br />

area (more than<br />

100Ω m)<br />

(ii) Pipe lines having FBE Coatings<br />

Pipeline<br />

Protection current density*<br />

surrounding Temporary CP Permanent CP<br />

(µA/m²)<br />

(MA/m²)<br />

Normal soil 200 0.300<br />

Marshy area 300 0.500<br />

High resistivity<br />

150 0.250<br />

area (more than<br />

100Ω m)<br />

Pipe to soil "ON" potential shall not be more negative than (-) 1.5V.<br />

* Actual current density to be adopted shall be decided based upon soil and other<br />

environmental conditions, proximity <strong>of</strong> foreign pipelines and structures affecting<br />

interference. Where considered necessary for satisfactory protection <strong>of</strong> pipeline the<br />

current density shall be suitably increased by contractor.<br />

4.2 Safety factor for current density : 1.3<br />

4.3 Anode utilisation factor : 0.65 for Mg. Anode<br />

0.80 for Zn Anode<br />

4.4 Pipeline natural potential : (-) 0.45 V<br />

4.5 Unless otherwise specified in project specification the design life <strong>of</strong> temporary CP shall<br />

be one year and that <strong>of</strong> permanent CP shall be 30 years.<br />

D:\old data\FATEH\MP Region\Kailaras\Tender RFQ\TCP&PCP\Temporary Cathodic Protection - 016A-R1.doc