MECON LIMITED<br />

REGD. OFF: RANCHI (BIHAR)<br />

PROCESS & PIPING<br />

DESIGN SECTION<br />

NEW DELHI<br />

TITLE PIPING FABRICATION AND<br />

ERECTION<br />

1.6 Calibration<br />

STANDARD SPECIFICATION<br />

SPECIFICATION NO. PAGE 53 OF 62<br />

MEC/S/05/62/06 REVISION 0<br />

For a precise check <strong>of</strong> the sound paths necessary for a full inspection <strong>of</strong> the<br />

weld joint, the probe shall be moved (half skip and full skip distance) until<br />

internal and external notches on the test piece are detected (see Fig. 5 <strong>of</strong> this<br />

specification).<br />

The relevant defect limits the path lengths on the time base. The calibration <strong>of</strong><br />

reference sensitivity is obtained by utilising the through drilled test hole in the<br />

thickness <strong>of</strong> the reference block to draw the distance amplitude correction curve<br />

relevant to the test probe.<br />

Calibration shall be carried out according to the following procedure : place its<br />

internal vertex until the maximum height <strong>of</strong> echo is displayed on the screen; this<br />

echo is adjusted to 80% <strong>of</strong> full screen height by means <strong>of</strong> the sensitivity adjuster<br />

set in dB. Without varying the amplification, the probe placed at full skip distance<br />

from the hole is moved to detect the external vertex the hole until the maximum<br />

height <strong>of</strong> echo is obtained. The straight line connecting the peaks <strong>of</strong> the two<br />

echoes obtained by the above procedure, represents the 100% reference level,<br />

while the one connecting the two points at half height <strong>of</strong> the same echoes<br />

represents "50% reference level".<br />

The two straight lines shall be marked on the screen with a pen. Calibration<br />

shallbe repeated each time tests are re-started at intervals not longer than 30<br />

minutes during normal operations; each time the conditions fixed in advance are<br />

altered. This calibration is applicable provided that the crystal <strong>of</strong> the probe is 8 x<br />

9mm size. Should this size <strong>of</strong> the crystal be different, the value <strong>of</strong> the sensitivity<br />

obtained from the calibration by a crystal <strong>of</strong> a different size shall be brought to<br />

the value <strong>of</strong> sensitivity obtained from the calibration by a 8 x 9mm crystal. The<br />

sensitivities <strong>of</strong> the two different size probes shall be compared through the<br />

echoes obtained on the notch <strong>of</strong> the test piece with the probe position at half<br />

skip <strong>of</strong> the distance.<br />

1.9 Regulation <strong>of</strong> Amplification during Production Testing<br />

The amplification during production testing shall be obtained by adding 2-6 dB<br />

(according to the surface condition <strong>of</strong> the pipe and its cleanness) to the<br />

reference amplification.