5.0 TESTS ON SOIL SAMPLES<br />

Soil/ water samples shall be collected along the right <strong>of</strong> way for<br />

analysis. Samples shall be collected on an average at one location per<br />

every 10 km along right <strong>of</strong> way with minimum at two locations. Exact<br />

locations shall be decided at site depending on the type <strong>of</strong> soil, soil<br />

resistivity and in consultation with Owner or his representative. The<br />

soil samples shall be collected at 1 mtr and 2 mtr depth at each<br />

location.<br />

The collected soil/ water samples shall be analysed to determine<br />

presenceand percentage <strong>of</strong> corrosive compounds including moisture<br />

content, oxygen activity and pH value.<br />

6.0 ADDITIONAL DATA COLLECTION<br />

The following data shall be collected with a view to generate design<br />

data <strong>of</strong> evaluation <strong>of</strong> cathodic protection interaction possibilities due to<br />

presence <strong>of</strong> other services in right <strong>of</strong> way and its vicinity.<br />

6.1 Route and types <strong>of</strong> foreign service/ pipelines in and around or crossing<br />

the right <strong>of</strong> way.<br />

6.2 Diameter, wall thickness, pressure, soil cover etc. <strong>of</strong> the foreign<br />

pipeline.<br />

6.3 Voltage rating, phases and sheathing details <strong>of</strong> parallel running or<br />

crossing cables with ROW.<br />

6.4 Foreign pipeline coating details.<br />

6.5 Details <strong>of</strong> exiting cathodic protection systems protecting the services<br />

including rating and location <strong>of</strong> grounds bed test station locations and<br />

connections schemes etc. Where pipeline is likely to pass close to any<br />

existing ground bed, necessary anode-bed potential gradient survey<br />

shall be carried out.<br />

6.6 Interference remedial measures existing on foreign pipelines/ services/<br />

shall be collected from the owner <strong>of</strong> the foreign pipeline/ services.<br />

D:\old data\FATEH\MP Region\Kailaras\Tender RFQ\TCP&PCP\Specification - Corrosion Survey - 016C.doc<br />

Page 3 <strong>of</strong> 5