- One coat <strong>of</strong> F-9 shall be applied wherever damaged was observed<br />

on pre-erection/ pre-fabrication/ shop primer <strong>of</strong> inorganic zinc<br />

silicate coating (F-9) shall not be applied if damaged area is not<br />

more than 5 x 5 cm.<br />

5.10 PAINT APPLICATION<br />

5.10.1 Shop priming/ pre-erection priming with F9 <strong>of</strong> F12 shall be done only on<br />

blasted surface.<br />

5.10.2 Shop priming/ pre-erection priming with F-9 or F-12 shall be done only<br />

with airless spray.<br />

5.10.3 For large flat surface field painting shall be done by airless spray<br />

otherwise brush can be used.<br />

5.11 Documentation.<br />

1. A written quality plan with procedure for qualification trials and for the<br />

actual work.<br />

2. Daily progress report with dedtails <strong>of</strong> weather condition, particular <strong>of</strong><br />

application no <strong>of</strong> coats and type <strong>of</strong> materials applied, anomolies, progress<br />

<strong>of</strong> work versus programme.<br />

3. Result <strong>of</strong> measurement <strong>of</strong> temperature relative humidity, surface pr<strong>of</strong>ile,<br />

film thickness, holiday detection, adhesion tests with signature <strong>of</strong><br />

appropriate authority.<br />

4. Particular <strong>of</strong> surface preparation and paint application during trials and<br />

during the work.<br />

5. Details <strong>of</strong> non-compliance, rejects and repairs.<br />

6. Type <strong>of</strong> testing equipments and calibration.<br />

7. Code and batch numbers <strong>of</strong> paint material used.<br />

Page 12 <strong>of</strong> 49