MECON LIMITED<br />

REGD. OFF : RANCHI (BIHAR)<br />

PROCESS & PIPING<br />

DESIGN SECTION<br />

NEW DELHI<br />

STANDARD SPECIFICATION<br />

TITLE WELDING OF ONSHORE GAS<br />

SPECIFICATION NO. PAGE 29 OF 48<br />

PIPELINES<br />

MEC/S/05/62/02 REVISION<br />

15.9 Regulation <strong>of</strong> Amplification During Production Testing<br />

The amplification during production testing shall be obtained by adding 2-6 dB<br />

(according to the surface condition <strong>of</strong> the pipe and its cleaness) to the reference<br />

amplification.<br />

15.10 Qualification <strong>of</strong> Ultrasonic Testing Operators<br />

Before the inspection begins or during the same inspection, the COMPANY may<br />

require a qualification test for the ultrasonic equipment operators.<br />

15.11 Evaluation <strong>of</strong> Indications Given by Ultrasonic Tests<br />

Each time that echoes from the weld bead appear during production testing, the<br />

instrument amplification shall be altered to coincide with the reference<br />

amplification and the probe shall be oved until maximum response is obtained,<br />

paying attention all the time <strong>of</strong> the probe-tube coupling.<br />

If, under these conditions, the heights <strong>of</strong> the defect echo is equal to or greater<br />

than that <strong>of</strong> the reference echo, the defect shall be evaluated according to other<br />

clauses <strong>of</strong> this Specification. If the defect has also been detected by the<br />

radiographic and or visual examination, the dimensions shall be judged<br />

according to the type <strong>of</strong> examination which detects the greater defect. Returns<br />

which are less that 50% <strong>of</strong> the reference echo, will not be considered. If returns<br />

are above 50% but lower than 100% <strong>of</strong> the reference echo, and if the operator<br />

has good reasons to suspect that the returns are caused by unfavourably<br />

oriented cracks, the same shall be informed to the COMPANY. Moreover, when<br />

there is a defect to be repaired, such defect shall be removed for a length<br />

corresponding to the one where no more return echo is given.<br />

15.12 Other Equipment<br />

The use <strong>of</strong> rules calibrated in centimeters, attached if possible to the probe, for<br />

the precise location <strong>of</strong> the position <strong>of</strong> welding defects, is recommended. Defect<br />

location is effected by measuring the projection distance between the probe<br />

output and the reflecting surface.<br />

\\Akjha\work contrac\standard TS for Pipe Line WC (Vol-<strong>II</strong>) MASTER FOLDER\02A welding onshore gas pipeline\Welding <strong>of</strong> Onshore Gas Pipelines with addendum - I 02A.doc