Pipe Size, Outside<br />

diameter<br />

Inches<br />

Tensile<br />

API<br />

Table-I<br />

TYPE AND NUMBER OF TEST SPECIMENS FOR<br />

PROCEDURE QUALIFICATION TEST<br />

Tensile<br />

ISO<br />

Nick<br />

Break<br />

Root<br />

Bend<br />

Number <strong>of</strong> Specimens<br />

Face<br />

Bend<br />

Side<br />

Bend<br />

Wall Thickness > ½ inch (12.7mm) and under<br />

Macro Hardness<br />

Impact Total<br />

Under 2 3/8 0 0 2 2 0 0 0 0 0 4<br />

2 3/8 to 4½ incl. 0 0 2 2 0 0 0 0 0 4<br />

Over 4½ less than<br />

12 3/4<br />

2 0 2 2 2 0 2 2 12 24<br />

12 3/4 and over 2 2 4 4 4 0 2 2 24 44<br />

Wall Thickness > ½ inch (12.7mm)<br />

4½ and smaller 0 2 0 0 0 2 0 0 0 4<br />

Over 4½ less than<br />

12 3/4<br />

2 0 2 2 2 0 2 2 12 24<br />

12 3/4 and over 2 2 4 0 0 8 2 2 24 44<br />

1.2 Tensile Strength<br />

Specimens for pipe diameter over 12 3/4" shall be taken from the<br />

position indicated in Fig. 1 <strong>of</strong> this specification. Two API type specimen<br />

shall be taken for pipe diameter greater than or equal to 12 3/4".<br />

1.3 Nick-Break Test<br />

1.3.1 Preparation<br />

Specimens for nick-break test with notches thus worked can break in<br />

the base metal, instead <strong>of</strong> in the fusion zone; therefore an alternative<br />

test piece may be used after authorisation by the COMPANY with a<br />

notch cut in the reinforcement <strong>of</strong> outside weld bead to a maximum<br />

depth <strong>of</strong> 1.5mm measured from the surface <strong>of</strong> the weld bead.