MECON LIMITED<br />

Delhi<br />

PROCESS & PIPING<br />

DESIGN SECTION<br />

TECHNICAL SPECIFICATION FOR<br />

PERMANENT CATHODIC<br />

PROTECTION SYSTEM<br />

TECHNICAL SPECIFICATION NO. : MEC/TS/05/62/016B REV-1 Page 14 <strong>of</strong> 24<br />

7.10 Cables<br />

After preparation <strong>of</strong> the under surface, spray painting with two coats <strong>of</strong> final paint<br />

shall be done. The finished panels shall be dried in ovens in dust free atmosphere.<br />

Panel finish shall be free from imperfections like pinholes, orange peels, run<strong>of</strong>f paint<br />

etc. Bidder shall furnish detailed painting procedure alongwith bids.<br />

All unpainted steel parts shall be cadmium plated to prevent rust formation.<br />

i) Cables shall be annealed high conductivity tinned stranded copper conductor,<br />

XLPE insulated, PVC sheathed, 650/1100 V grade, armoured for<br />

Cathode/Anode / measurement cable. Unless otherwise specified in project<br />

specifications, the size <strong>of</strong> the copper conductor shall be minimum 35 sq. mm.<br />

for anode and cathode cables, 6 sq. mm. for potential measurement and<br />

reference cells, 10 sq. mm. for current measurement, 25 sq. mm. for bonding/<br />

grounding and 10 sq. mm. for anode tail cables. The anode tail cables shall be<br />

XLPE insulated & PVC sheathed and not be armoured and length shall be<br />

sufficient for termination on anode lead junction box without any joint. PE<br />

sleeves shall be provided for unarmoured cables.<br />

ii) The T/R unit incomer cable shall be minimum 10 sq. mm. aluminium, 650/1100<br />

V PVC insulated, armoured, PVC sheathed.<br />

7.11 Panel Cabling and cable glands<br />

Adequate space shall be provided inside the panel for termination <strong>of</strong> cables.<br />

Termination shall be performed using crimped lugs. Tags with cable numbers<br />

engraved on it shall be attached to each cable at both ends. Cable glands shall be<br />

double compression type <strong>of</strong> Nickel/ Chromium plated brass. The lugs shall be <strong>of</strong> tinned<br />

copper. Phases <strong>of</strong> AC power cables shall be identified with red, yellow, blue PVC<br />

adhesive material.<br />

The armour <strong>of</strong> the cables from pipeline to CP station (potential measurement,<br />

reference cell & drainage cables etc.), CP station to ground bed (anode cable) and test<br />

station to pipeline shall be earthed only at one end <strong>of</strong> the cable to avoid armour<br />

carrying CP current.<br />

8.0 INSTALLATION<br />

8.1 Cable Laying<br />

j) Cables shall be laid in accordance with approved layout drawings to be<br />

prepared by the contractor. No straight through joint shall be permitted in a<br />

single run <strong>of</strong> cable. Cable route shall be carefully measured and cables cut to<br />

required length. Enough slackness in cable shall be provided near anodes to<br />

account for any settling <strong>of</strong> anode.<br />