MECON LIMITED<br />

Delhi<br />

PROCESS & PIPING<br />

DESIGN SECTION<br />

TECHNICAL SPECIFICATION FOR<br />

TEMPORARY CATHODIC<br />

PROTECTION SYSTEM<br />

TECHNICAL SPECIFICATION NO. : MEC/TS/05/62/016A REV-1 Page 2 <strong>of</strong> 19<br />

NACE publications<br />

IEC publications<br />

DNV publications<br />

IEEE publications<br />

DIN publications<br />

ASTM publications<br />

In case <strong>of</strong> conflicting requirements amongst any <strong>of</strong> the above standards the<br />

publication having most stringent requirement shall be governing.<br />

3.0 CORROSION DATA<br />

3.1 The corrosion survey including soil resistivity data along ROW and other data required<br />

for CP design is attached with this document. However, verification <strong>of</strong> its veracity and<br />

adequacy shall be the entire responsibility <strong>of</strong> the contractor. In addition, contractor<br />

shall have to generate/ collect additional data as required for completeness <strong>of</strong> the job.<br />

Contractor shall also carry out soil resistivity survey at temporary mode ground bed<br />

locations for proper design <strong>of</strong> ground beds. Wenner's 4-pin method or approved equal<br />

shall be used for such measurements. Survey instruments shall have maximum AC and<br />

DC ground current rejection feature.<br />

3.2 Additional data to be collected<br />

The following data shall be collected to generate design data for evaluation <strong>of</strong><br />

interaction/ interference possibilities due to presence <strong>of</strong> other services in ROW/ in<br />

vicinity.<br />

i. Route and types <strong>of</strong> foreign service/pipeline in and around or crossing the right<br />

<strong>of</strong> way (including those existing and those which are likely to come up during<br />

contract execution or any abandoned pipelines.<br />

ii. Diameter, wall thickness, pressure, pipeline coating against corrosion, soil<br />

cover used in case <strong>of</strong> pipelines.<br />

iii. Detail <strong>of</strong> the existing cathodic protection system protecting the services i.e.<br />

location, rating, type <strong>of</strong> protection, anode beds, test station locations and their<br />

connection schemes.<br />

iv. Graphical representation <strong>of</strong> existing structure/ pipe-to soil potential records.<br />

T/R unit current/ voltage readings.<br />

v. Remedial measures existing on foreign pipeline/services to prevent interaction.<br />

vi. Possibility <strong>of</strong> intergration/isolation <strong>of</strong> CP system, Which may involve<br />

negotiations with owners <strong>of</strong> other services.<br />

D:\old data\FATEH\MP Region\Kailaras\Tender RFQ\TCP&PCP\Temporary Cathodic Protection - 016A-R1.doc