Property Test<br />

Method<br />

Condition Requirement<br />

Peel Strength<br />

DIN 30672 23°C. CHS* 200 N/cm minimum<br />

After immersion for 4 weeks<br />

at 23°C~NaOH pH12 H2SO4<br />

pH2 ground water solution:-<br />

1.2% H3PO4<br />

1.6% KOH<br />

1.2NaCl<br />

1.0% Fe2O3<br />

100 mm/ min.<br />

Peel Strength after<br />

DIN 30672 23°C. CHS* 60 N/cm minimum<br />

conditioning for 30<br />

cycles from -30°C to 60°C<br />

100 mm/ min.<br />

Shear strength ISO 4587 23°C. CHS*<br />

50 mm/ min.<br />

Corrosive effect ASTM D 120°C.<br />

2671 16 hrs.<br />

3.2.3 Primer Material<br />

200 N/cm 2 minimum<br />

No corrosion<br />

Property Test Method Condition Requirement<br />

Density ASTM D1084 23 +/- 0.5 0 C<br />

Part A: 2 rpm, spindle #6<br />

Part B: 20rpm, spindle #3<br />

Part A: 60+/- 30 Pas<br />

Part B: 1.55+/-0.55 Pas<br />

Mixing ratio By weight 23°C 100:40<br />

By volume<br />

100:60<br />

Shear strength ISO 4587 23°C. CHS*<br />

50 mm/ min.<br />

1000 N/cm 2 minimum<br />

* CHS = Cross Head Speed<br />

3.2.4 Functional Properties<br />

Sl.<br />

No.<br />

Property Test Method Condition Requirement<br />

a) Impact<br />

DIN 30672 23°C. No holidays when tested<br />

resistance<br />

Class C at 20 KV<br />

b) Penetration DIN 30672 60°C. Minimum 70% <strong>of</strong> original<br />

resistance<br />

Class C resistance thickness left;<br />

no holidays when tested<br />

at 20 KV<br />

c) Specific coating DIN 30672 23°C. 10<br />

resistance<br />

8 Ohm sq. m minimum;<br />

no oxidation on pipe<br />

surface<br />

d) Cathodic<br />

ASTM G42 60°C. 15 mm increase in radius<br />

disbondment<br />

resistance<br />

30 days <strong>of</strong> disbondment max.<br />

e) Resistance to<br />

split<br />

propagation<br />

TEST METHOD-<br />

1 *<br />

No cut propagation<br />