MECON LIMITED<br />

Delhi<br />

PROCESS & PIPING<br />

DESIGN SECTION<br />

TECHNICAL SPECIFICATION FOR<br />

TEMPORARY CATHODIC<br />

PROTECTION SYSTEM<br />

TECHNICAL SPECIFICATION NO. : MEC/TS/05/62/016A REV-1 Page 12 <strong>of</strong> 19<br />

6.6 Painting<br />

6.7 Cables<br />

casing. The anode installation shall be sized based on permanent C.P. design<br />

parameters specified for the main pipeline.<br />

The carrier pipe inside the casing shall be protected by zinc ribbon anodes well<br />

connected to the outer surface <strong>of</strong> bottom <strong>of</strong> carrier pipe extending upto hour hand<br />

positions <strong>of</strong> 4 and 8 o'clock. The anodes shall be placed at close intervals as per<br />

design parameters calculations and sized based on the permanent CP design<br />

parameters.<br />

The sheet steel used for fabrication shall be thoroughly cleaned and degreased to<br />

remove mill scale, rust, grease and dirt. Fabricated structures shall be pickled and then<br />

rinsed to remove any trace <strong>of</strong> acid. The under surfaces shall be prepared by applying a<br />

coat <strong>of</strong> phosphate paint and a coat <strong>of</strong> yellow zinc chromate primer. The under surfaces<br />

shall be free from all imperfections before undertaking the finished coat. After<br />

preparation <strong>of</strong> the under surface, spray painting with two coats <strong>of</strong> final paint shall be<br />

done. The finished panel shall be dried in oven in dust free atmosphere. Panel finish<br />

shall be free from imperfections like pin holes, orange peels, run <strong>of</strong>f paint, etc.<br />

All unpainted steel parts shall be cadmium plated to prevent rust information.<br />

Cables shall be annealed high conductivity, tinned, stranded copper conductor, XLPE<br />

insulated 650/1100 V grade, armoured, PVC sheathed. The size <strong>of</strong> the copper<br />

conductor shall be 6 sq mm for anode cable from anode to buried junction box, 10 sq<br />

mm from junction box to test station, 10mm² from test station to pipeline. The size <strong>of</strong><br />

the conductor shall be 6 sq mm for potential measurement, 10 sq.mm for current<br />

measurement and 25mm² for bonding, polarisation cell/grounding cell and surge<br />

diverter connection purpose. The anode cable from anode to junction box (buried)<br />

shall be unarmoured. The length <strong>of</strong> anode tail cable shall be sufficient enough to reach<br />

junction box (buried) in case <strong>of</strong> temporary CP anodes and up to test station in case <strong>of</strong><br />

permanent CP sacrificial anodes. PE Sleeves shall be provided for unarmoured cables.<br />

7.0 INSTALLATION<br />

7.1 Cable Laying<br />

7.1.1 Cables shall be laid in accordance with approved layout drawings to be prepared by<br />

the contractor. No straight through joint shall be permitted in a single run <strong>of</strong> cable.<br />

Cable route shall be carefully measured and cables cut to required length.<br />

7.1.2 All cables inside station/plant area shall be laid at a depth <strong>of</strong> 0.75 M. Cables outside<br />

station/plant area shall be laid at a depth <strong>of</strong> 1.5m. Cables shall be laid in sand under<br />

D:\old data\FATEH\MP Region\Kailaras\Tender RFQ\TCP&PCP\Temporary Cathodic Protection - 016A-R1.doc