28.01.2014 Views

m-Cresol - ipcs inchem

m-Cresol - ipcs inchem

m-Cresol - ipcs inchem

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

OECD SIDS<br />

p-CRESOL<br />

3. ENVIRONMENTAL FATE AND PATHWAYS ID: 106-44-5<br />

DATE: 24.05.2004<br />

Test substance : other TS: p-cresol, purity not noted<br />

Deg. products : 74-82-8 200-812-7 methane<br />

Remark : sensitivity of acid formers and methanogenic consortia examined<br />

Result : Mineralization occurred after 15 days at a concentration of<br />

100 ppm p-cresol. Duration of mineralization increased to 39 days at a<br />

concentration of 400 ppm p-cresol.<br />

Test condition : TS concentrations: 200, 400, and 1000 mg/l<br />

incubation for 6 weeks at 37 degrees C<br />

Reliability : (4) not assignable<br />

No standard test procedure, but in accordance with generally accepted<br />

scientific standards, not relevant for purpose of HPV program<br />

24.05.2004 (55)<br />

Type : aerobic<br />

Inoculum : other: acclimated mixed microbial culture<br />

Concentration : .4 mg/l related to Test substance<br />

3.2 mg/l related to Test substance<br />

Contact time : 20 day(s)<br />

Degradation : (±) % after<br />

Result :<br />

Deg. product :<br />

Method : other: APHA 1980<br />

Year : 1987<br />

GLP : no<br />

Test substance : other TS: p-cresol, no purity reported<br />

Result : BOD (5 days) = 5.63 mmol O2/mmol TS<br />

ThBOD = 8.50 mmol O2/mmol TS<br />

Test condition : 21 +- 3 degrees C<br />

Reliability : (4) not assignable<br />

Documention insufficient for assessment<br />

24.05.2004 (56)<br />

Type : aerobic<br />

Inoculum : other bacteria: Aufwuchs communitiy<br />

Deg. product : not measured<br />

Method :<br />

Year : 1987<br />

GLP : no<br />

Test substance : other TS: p-cresol, purity at least 99 %<br />

Method : Estimation of biotransformation kinetics in natural waters.<br />

Aufwuchs colonized for 5 months on Teflon strips at 2 rivers and 2 ponds.<br />

Strips were returned to laboratory, and<br />

fastened into a beaker containing autoclaved natural water.<br />

Beakers spiked with 100 and 200 µg/l test substance at 20<br />

degrees C. TS detected by HPLC.<br />

Result : A great variability for the k values (for individual sample<br />

sites between -5.1 and -3388 h-1) was found. Mean values for the sites:<br />

pond 1: k = -273.1 h-1<br />

pond 2: k = -95.5 h-1<br />

river 1: k = -1637.1 h-1<br />

river 2: k = -70 h-1<br />

Reliability : (2) valid with restrictions<br />

No standard test procedure, but in accordance with generally<br />

accepted scientific standards and described in sufficient<br />

detail<br />

11.05.2004 (57)<br />

Type : aerobic<br />

UNEP PUBLICATIONS 211

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!