OECD SIDS<br />

p-CRESOL<br />

4. ECOTOXICITY ID: 106-44-5<br />

DATE: 24.05.2004<br />

GLP : no<br />

Test substance : other TS: p-cresol, no purity reported<br />

Result : EbC10 = 2.3 mg/l<br />

ErC10 = 4.6 mg/l<br />

EbC50 = 7.8 mg/l<br />

ErC50 = 21 mg/l<br />

Test condition : 24 +- 1 degrees C; TS concentration 0.8 - 100 mg/l, dilution<br />

series 1:2<br />

preliminary culture 10E5 cells/,l<br />

irradiance 17.0 W/m2<br />

Reliability : (2) valid with restrictions<br />

Test procedure according to national guideline<br />

Flag : Critical study for SIDS endpoint<br />

07.05.2004 (99)<br />

Species : Chlorella pyrenoidosa (Algae)<br />

Endpoint : other: chlorophyll content<br />

Exposure period : 72 hour(s)<br />

Unit : mg/l<br />

EC0 : < 50<br />

EC50 : 116<br />

EC100 : 250<br />

Limit test : no<br />

Analytical monitoring : no<br />

Method :<br />

Year : 1968<br />

GLP : no<br />

Test substance : other TS: p-cresol, no purity reported<br />

Result : Complete destruction of chlorophyll at 1000 mg/l after 1 day.<br />

EC50 was not reported in the study, but it can be taken from the graph<br />

Test condition : TEST ORGANISMS<br />

- Strain: Emerson strain<br />

- Test temperature: 25 +- 1 degrees C<br />

- pH: 7.0<br />

- Photoperiod: continuous illumination<br />

TEST PARAMETER: chlorophyll<br />

Reliability : (2) valid with restrictions<br />

Study in accordance with generally accepted scientific<br />

standards and described in sufficient detail<br />

12.05.2004 (100)<br />

Species : other aquatic plant: Potamogeton coloratus<br />

Endpoint : other: photosynthesis<br />

Exposure period : 21 day(s)<br />

Unit : mg/l<br />

NOEC : < .22<br />

LOEC : = .22<br />

EC50 : > 1.08<br />

Limit test :<br />

Analytical monitoring : no<br />

Method :<br />

Year : 1983<br />

GLP : no<br />

Test substance : other TS: p-cresol, no purity reported<br />

Method : simulation of running water under summer climate conditions<br />

Test condition : water hardness: 9° dH; conductivity: 300 µS; pH 7.8<br />

Reliability : (3) invalid<br />

Methodological deficiencies. Most test conditions not indicated. No<br />