OECD SIDS<br />

m- / p-CRESOL MIXTURE<br />

3. ENVIRONMENTAL FATE AND PATHWAYS ID: 15831-10-4<br />

DATE: 24.05.2004<br />

%<br />

Control substance : other: phenol, 0.8 mg/l<br />

Kinetic : 28 day(s) = 73 %<br />

%<br />

Deg. product :<br />

Method : OECD Guide-line 301 D "Ready Biodegradability: Closed Bottle Test"<br />

Year : 1988<br />

GLP : no<br />

Test substance : other TS: m-cresol pure<br />

Result : 10-day window criteria is met<br />

Test condition : Inoculum<br />

- Type of sludge: activated sludge<br />

- Source: treatment plant, receiving domestic sewage<br />

- Sampling site: Odenthal<br />

Concentration of control substance: 0.8 mg/l<br />

Analytical parameter: Oxygen consumption<br />

Test temperature: 20 degrees C<br />

Test was performed in two paralleles.<br />

Reliability : (2) valid with restrictions<br />

Guideline Study<br />

Flag : Critical study for SIDS endpoint<br />

12.05.2004 (22)<br />

Type : aerobic<br />

Inoculum : predominantly domestic sewage<br />

Concentration : 2.4 mg/l related to COD (Chemical Oxygen Demand)<br />

related to<br />

Contact time :<br />

Degradation : = 65 (±) % after 28 day(s)<br />

Result :<br />

Kinetic of testsubst. : 7 day(s) = 55 - 58 %<br />

14 day(s) = 58 - 66 %<br />

21 day(s) = 61 - 65 %<br />

28 day(s) = 65 - 65 %<br />

%<br />

Control substance : other: phenol, 2.4 mg/l<br />

Kinetic : 28 day(s) = 69 %<br />

%<br />

Deg. product :<br />

Method : OECD Guide-line 301 D "Ready Biodegradability: Closed Bottle Test"<br />

Year : 1988<br />

GLP : no<br />

Test substance : other TS: m-cresol pure<br />

Remark : In two further tested concentrations (8 and 24 mg/l) the<br />

dissolved oxygen was completely emaciated within 7 days<br />

(concentration of control substance 8 and 24 mg/l for tests<br />

with 8 and 24 mg/l of test substance, respectively. Also i n<br />

these control experiments, oxygen was emaciated).<br />

Result : Compared to the test with 0.8 mg/l the extent of degradation<br />

is lesser at 2.4 mg/l presumably due to the fact that most<br />

of the oxygen was used up at the high test substance<br />

concentration<br />

Test condition : Inoculum / test organism<br />

- Type of sludge: activated sludge<br />

- Source: treatment plant, receiving domestic sewage<br />

- Sampling site: Odenthal<br />

Concentration of control substance: 2.4 mg/l<br />

Analytical parameter: Oxygen consumption<br />

Test temperature: 20 degrees C<br />