<strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong> Introducing the Products 1-5<br />

Error Reactions of the <strong>Drive</strong><br />

Clearing Error Messages<br />

Clearing Error Messages when<br />

<strong>Drive</strong> Enable Was Set<br />

Error Memory<br />

DOK-INDRV*-FU*********-IB01-EN-P<br />

during firmware download. These errors are not displayed at<br />

the control panel with a diagnostic message number of the<br />

"Fxxxx" pattern, but with a short text. Boot errors and firmware<br />

download errors are separately described in the<br />

documentation "Troubleshooting Guide" (diagnostic message<br />

description).<br />

If the drive controller is in control and an error status is detected, the<br />

execution of a drive error reaction is automatically started. The diagnostic<br />

message number "Fxxxx" flashes on the display of the control panel.<br />

The drive reaction in the case of interface errors and non-fatal errors is<br />

determined in parameter P-0-0119, Best possible deceleration At the<br />

end of each error reaction, the drive is torque-free.<br />

See also "Error Reactions" in chapter "<strong>Drive</strong> Functions"<br />

Error messages are not cleared automatically but by the following action:<br />

• activating the S-0-0099, C0500 Reset class 1 diagnostics command<br />

- or -<br />

• actuating the "Esc" button on the control panel<br />

If the error status persists the error message is immediately generated<br />

again.<br />

If a drive error occurs while operating with drive enable having been set,<br />

the drive carries out an error reaction. The drive automatically deactivates<br />

itself at the end of each error reaction; in other words, the output stage is<br />

switched off and the drive switches from an energized to a de-energized<br />

state.<br />

To reactivate the drive:<br />

• clear the error message and<br />

• input a positive edge for drive enable again.<br />

The diagnostic message numbers of occurring errors are written to an<br />

error memory. This memory contains the diagnostic message numbers of<br />

the last 50 errors that occurred and the time when they occurred. Errors<br />

caused by a shutdown of the control voltage (e.g. F8070 +24Volt DC<br />

error) are not stored in the error memory.<br />

The diagnostic message numbers in the error memory are mapped to the<br />

P-0-0192, Diagnostic numbers of error memory parameter and can be<br />

displayed by means of the control panel. By means of the "IndraWorks D"<br />

commissioning tool it is possible to display the diagnostic message<br />

numbers and the respective times at which the errors occurred.